Variables influencing the prediction of fluid responsiveness: a systematic review and meta-analysis

verfasst von: Jorge Iván Alvarado Sánchez, Juan Daniel Caicedo Ruiz, Juan José Diaztagle Fernández, Luís Eduardo Cruz Martínez, Fredy Leonardo Carreño Hernández, Carlos Andrés Santacruz Herrera, Gustavo Adolfo Ospina-Tascón

Erschienen in: Critical Care | Ausgabe 1/2023

Abstract

Introduction

Prediction of fluid responsiveness in acutely ill patients might be influenced by a number of clinical and technical factors. We aim to identify variables potentially modifying the operative performance of fluid responsiveness predictors commonly used in clinical practice.

Methods

A sensitive strategy was conducted in the Medline and Embase databases to search for prospective studies assessing the operative performance of pulse pressure variation, stroke volume variation, passive leg raising (PLR), end-expiratory occlusion test (EEOT), mini-fluid challenge, and tidal volume challenge to predict fluid responsiveness in critically ill and acutely ill surgical patients published between January 1999 and February 2023. Adjusted diagnostic odds ratios (DORs) were calculated by subgroup analyses (inverse variance method) and meta-regression (test of moderators). Variables potentially modifying the operative performance of such predictor tests were classified as technical and clinical.

Results

A total of 149 studies were included in the analysis. The volume used during fluid loading, the method used to assess variations in macrovascular flow (cardiac output, stroke volume, aortic blood flow, volume‒time integral, etc.) in response to PLR/EEOT, and the apneic time selected during the EEOT were identified as technical variables modifying the operative performance of such fluid responsiveness predictor tests (p < 0.05 for all adjusted vs. unadjusted DORs). In addition, the operative performance of fluid responsiveness predictors was also influenced by clinical variables such as the positive end-expiratory pressure (in the case of EEOT) and the dose of norepinephrine used during the fluid responsiveness assessment for PLR and EEOT (for all adjusted vs. unadjusted DORs).

Conclusion

Prediction of fluid responsiveness in critically and acutely ill patients is strongly influenced by a number of technical and clinical aspects. Such factors should be considered for individual intervention decisions.
Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1186/​s13054-023-04629-w.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
ABF
Aortic blood flow
APACHE II
Acute physiology and chronic health evaluation score II
AUC
Area under the curve
CI
Cardiac index
CO
Cardiac output
cIVC
Inferior vena cava collapsibility index
DVpeakP
Brachial artery peak velocity
Delta-PI
Delta perfusion index
delta-VF
Peak velocity of femoral artery flow
DORs
Diagnostic odds ratios
EEOT
End-expiratory occlusion test
ETCO2
End-tidal carbon dioxide
FR
Fluid responsiveness
FPR
Predictor of fluid responsiveness
FTC
Flow time corrected
IVC max
Maximum inferior vena cava diameter
OP
Operative performance
PEEP
Positive end-expiratory pressure
PI
Perfusion index
PP
Pulse pressure
PRISMA
Preferred Reporting Items for Systematic Reviews and Meta-Analysis
PLR
Passive leg raising
PP
Pulse pressure
PPV
Pulse pressure variation
PVI
Respiratory variation of PI
SAPS II
Simplified acute physiology score II
SV
Stroke volume
SVI
Stroke volume index
SVV
Stroke volume variation
VTI
Velocity–time integral
Vpeak
Peak velocity of the aortic velocity signal

Introduction

Fluid therapy is one of the first-line interventions used to reverse tissue hypoperfusion during acute circulatory failure. In general, fluid administration aims to increase cardiac output (CO), supposing that this will improve tissue perfusion and then cellular respiration and cell metabolism [1]. Nevertheless, excessive fluid administration may cause deleterious effects due to the induction of interstitial edema, impairment of microvascular flow, limitation of oxygen diffusion to the cells, increase in central venous pressure (which limits venous return), and increase in body distribution volumes. Indeed, fluid overload has been related to worse clinical outcomes, whereby fluids should be administered when a positive impact on macrohemodynamics is anticipated [2, 3].
A number of maneuvers have been described to assess fluid responsiveness in acutely and critically ill patients [2]. These include, among others, pulse pressure variation (PPV), stroke volume variation (SVV), variations in cardiac output or pulse pressure after passive leg raising (PLR), end-expiratory transitory apnea in mechanically ventilated patients (i.e., the end-expiratory occlusion test, EEOT), rapid infusion of a low volume of fluids (i.e., the mini-fluid challenge, MFC), and transitory increases in tidal volumes in patients with reduced pulmonary compliance subjected to protective mechanical ventilation (i.e., the tidal volume challenge, VTC) [4]. In general, such predictive tests of fluid responsiveness have shown acceptable operative performances in different clinical settings [518]. Nonetheless, heterogeneity of populations, variety of clinical scenarios, and technical differences to assess fluid responsiveness might complicate its application to specific individual clinical contexts. [14, 15, 18]. Only a few studies have included subgroup analyses that allow the assessment of sources of heterogeneity or the evaluation of variations in the operative performance of individual tests [5, 6, 1518].
The performance of predictor tests to assess fluid responsiveness might be affected by a number of clinical and technical factors [17], which could lead to false positive or negative results with the subsequent increased risk of fluid overload or hypovolemia when such predictors are used to guide individual decisions. Although it is known that certain physiological variables might affect the performance of predictors of fluid responsiveness, few meta-analyses or meta-regressions have evaluated the variations in performance to predict fluid responsiveness in particular subgroups [5, 6, 1518]. Therefore, we aim to systematically assess the impact of clinical and technical variables potentially modifying the performance of predictor tests of fluid responsiveness in critically ill and perioperative adult patients using subgroup analysis and meta-regression.

Methods

Protocol

This meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) for diagnostic test accuracy (DTA) guidelines [19]. The complete predefined protocol was registered in PROSPERO (registration number CRD42021266950) (https://​www.​crd.​york.​ac.​uk/​prospero/​display_​record.​php?​ID=​CRD42021266950) in August 2021.

Search strategy and data extraction

A comprehensive search strategy was conducted using the Medline and Embase databases between January 1999 and February 2023. Data extraction and eligibility assessment were standardized and independently performed by two reviewers (J.I.A.S. and J.D.C.R.). Reference lists of selected manuscripts were also manually reviewed to search for potential studies not retrieved by the original search. No language restriction was applied. The complete search strategy and the terms used are available in the protocol uploaded to PROSPERO (registration number CRD42021266950).

Study selection and inclusion criteria

Studies were selected according to the PICOS statement as follows:
  • P-Patients and setting: We selected studies including critically ill and acutely ill perioperative patients. We excluded studies conducted in the emergency room and those including patients < 18 years of age and pregnant women.
  • I-index test: We selected studies evaluating the operative performance of PPV, SVV, PLR, EEOT, MFC, and VTC as predictors of fluid responsiveness. Studies evaluating PPV and SVV performance were selected when they included patients under mechanical ventilation without respiratory effort and arrhythmias. Meanwhile, studies evaluating PLR-induced changes in both cardiac output and pulse pressure, including patients with intra-abdominal hypertension (explicit definition), were not selected.
  • C-comparison or reference standard: Only studies including an explicit definition of fluid responsiveness (reference standard) after fluid loading or another maneuver (such as PLR or EEOT) were incorporated into the analysis.
  • O-outcomes or target condition: We selected only studies reporting data about the operative performance of any fluid responsiveness test. Some studies had several data points on operative performance; in such cases, all data regarding operative performance were included.
  • S-studies: We selected prospective studies. Meanwhile, case reports, studies with incomplete data, studies conducted in animals, studies assessing patients with heart failure, those including patients under one-lung ventilation or open chest surgery, and retrospective studies were excluded from the analysis.

Study selection and data collection process

Two authors (J.I.A.S. and J.D.C.R.) independently reviewed the titles and potentially eligible abstracts. Studies fulfilling the inclusion criteria were pooled in individual extraction sheets to be ultimately compared. Discrepancies about inclusion, quality, adequacy of data, and final classification of eligible studies were resolved by consensus among the authors.

Data Items

Data extracted from eligible studies included year of publication, authors, number of participants, sensitivity, specificity, area under the curve (AUC); method employed to assess preload dependency (i.e., excitation method): fluid challenge, PLR, EEOT and Trendelenburg; technique used to assess the selected excitation method; variable employed for appraising fluid responsiveness (i.e., the peri-excitation macrohemodynamic variable), and clinical setting. Variables potentially modifying the operative performance of predictors of fluid responsiveness were classified as technical and clinical. Technical variables included fluid loading > or ≤ 4 mL/kg; hemodynamic variables were used to determine the PLR/EEOT response, which were separated into two groups: (a) CO direct measurements: aortic blood flow (ABF), CO/cardiac index (CI), stroke volume (SV)/stroke volume index (SVI), and velocity–time integral (VTI); and (b) CO surrogates: pulse pressure (PP), SVV and PPV. Other technical variables included the time lapse of expiration during the EEOT maneuver (≤ 15 s, > 15 – < 30 s and ≥ 30 s); the threshold used to define fluid responsiveness (< or ≥ 10%); the use or not of thermodilution as a gold standard to measure CO; and whether the volume of MFC was considered a part of the fluid load during the FR assessment. Meanwhile, clinical variables included the type of patient, driving pressure, level of positive end-expiratory pressure (PEEP), tidal volume (Vt), total respiratory compliance, supine vs. prone position ventilation, and norepinephrine dose (< or ≥ 0.3 mcg/kg/min).

Risk of bias in individual studies

The quality of eligible studies was assessed according to the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) using 4 domains: patient selection, index test, reference standard, and flow and time. Each area was evaluated for risk of bias and classified as low, high, or unclear. Moreover, the risk of applicability was considered in three domains: patient selection, index test, and reference standard, which were in turn assessed as low, high, or unclear [20].

Statistical analysis

Analysis of individual studies

We computed the sensitivity, specificity, and diagnostic odds ratio (DOR) using a contingency table. In certain studies, operative performance was assessed in multiple subgroups, including different ventilation parameters, techniques used to assess fluid responsiveness, cutoff values to consider the test as positive, and methods for evaluating fluid response. In such cases, all the available data related to the operative performance were incorporated.
DORs were calculated as described elsewhere (21). Higher DORs identify predictors with higher sensitivity and specificity combined with lower rates of false positives and negatives.

Analysis of summary measures

Fitted data of sensitivity, specificity, and AUC were assessed by using bivariate and hierarchical analyses. The summary receiver operating characteristic (ROC) curve was assessed by the Rutter and Gatsonis method, while the AUC was graduated according to Fisher et al. [21]. Unadjusted DOR was calculated by using a random-effects model. Heterogeneity was evaluated by Cochran Q statistics; its effect was quantified by using inconsistency (I2).

Analysis of risk of bias across studies

Asymmetry was assessed by Egger tests [22]. Publication bias was fitted by the trim-and-fill method [23]

Subgroup analysis and meta-regression

Adjusted DORs were calculated by subgroup analyses (inverse variance method) and meta-regression (test of moderators) for all technical and clinical variables potentially influencing the operative performance of predictors of fluid responsiveness, as described above. Meta-regression was especially used to assess continuous variables such as Vt, lung compliance, PEEP, and driving pressure.

Additional analysis

A meta-regression was performed based on the quality assessment of all studies included (according to the QUADAS-2).
The sensitivity analysis is summarized in Table 4. It encompasses the measurement methods employed to assess the excitation method: continuous thermodilution/pulmonary artery catheter, transpulmonary thermodilution, calibrated/non-calibrated pulse contour analysis, bioimpedance/bioreactivity, and esophageal Doppler. Additionally, clinical settings, including cardiovascular, neurological, neurosurgical, other surgical, and sepsis contexts, were also considered. Furthermore, hemodynamic variables used to determinate the response to passive leg raising (PLR) or the end-expiratory occlusion test (EEOT) encompassed cardiac output, aortic blood flow, stroke volume, and velocity–time integral. Such variables were included as reported in each study and were identified as the primary sources of heterogeneity.
The Grading of Recommendations Assessment, Development, and Evaluations (GRADE) was performed as a diagnostic test [24]. The threshold effect was evaluated by Spearman´s rank correlation coefficient and by the Moses-Shapiro-Littenberg method [25]. Data were analyzed using R version 3.4.3 with the Meta-Analysis of Diagnostic Accuracy (MADA) and meta-packages. The data are expressed as a value (95% confidence interval [CI]). P < 0.05 was considered statistically significant.

Results

Study selection

From 857 preliminary records identified from the EMBASE and Medline databases and their reference lists and after removing duplicated records and studies not fulfilling the inclusion criteria, a total of 149 studies were finally included in the analysis (Fig. 1).

Study characteristics, risk of bias, and syntheses of results

A total of 6488 patients were included in the meta-analysis, with 7350 fluid challenges performed and an average fluid responsiveness of 53%. General characteristics of the included studies are described in the Additional file 1: Appendix: Table S1, while operative performance for different fluid responsiveness predictors is depicted in the Additional file 1: Appendix (Tables S2 – S7).
The risk of bias is depicted in Fig. 2 and the Additional file 1: Appendix (Table S8), while the operative performance of fluid responsiveness predictors is depicted in Table 1. The asymmetry assessment is depicted in the Additional file 1: Appendix (Table S9), while the asymmetry fitted by the trim-and-fill method is depicted in the Additional file 1: Appendix (Table S10). Studies assessing PPV, SVV, PLR, EEOT, and VTC showed significant asymmetry (p < 0.05).
Table 1
Unadjusted operative performance of predictor of fluid responsiveness evaluated
Predictor of fluid responsiveness
AUC
Sensitivity (95% CI)
Specificity (95% CI)
Unadjusted DOR (95% CI)
I2 (95% CI) (%)
Q
p value
PVV
0.84
0,77(0.74–0.80)
0.79(0.76–0.82)
16.6 (12.9 – 21.7)
52.8
216.2
 < 0.01
SVV
0.83
0.77(0.73–0.80)
0.78(0.74–0.82)
14.4(10.7–19.4)
52.9
144.42
 < 0.01
PLR
0.84
0.77(0.73–0.80)
0.80(0.75–0.83)
22.6(17.0–30.2)
53.7
181.85
 < 0.01
EEOT
0.83
0.76(0.70–0.81)
0.77(0.71–0.83)
17.8(10.7–30.0)
52.6
107.9
 < 0.01
MFC
0.90
0.85(0.79–0.90)
0.84(0.78–0.88)
37.3(21.8–64.0)
30.0
21.4
0.12
VTC
0.89
0.86(0.81–0.91)
0.80(0.74–0.85)
46.6(26.7–81.3)
28.5
33.25
0.09
AUC The area under curve, I2, Inconsistency, PPV Pulse pressure variation, Q Cochran Q statistics, SVV Stroke volume variation, PLR Passive leg raising, EEOT End-expiratory occlusion test, MFC Mini-fluid challenge, VTC Tidal volume challenge
Values are expressed as pooled data (95% confidence interval)
P–value was obtained by heterogeneity test
In general, heterogeneity was moderate for PPV, SVV, PLR, and EEOT (p = 0.01), and the studies that evaluated MFC and VTC were homogeneous (p > 0.05).

Subgroup analysis and meta-regression

Subgroup analysis and meta-regression are shown in Tables 2 and 3 and the Additional file 1: Appendix (Table S11).
Table 2
Adjusted operative performance of the technical variables for predictors of fluid responsiveness evaluated
Subgroup
Predictor evaluated
Number of studies
Unadjusted DOR (95%CI)
Adjusted DOR (95% CI)
P value by subgroup analysis
P value by meta-regression
I2(%)
Fluid loading > 4 ml/kg
Yes
No
PPV
85
14
16.6 (12.9 – 21.7)
19.4(14.5–26.0)
8.1(4.3–15,2)
 < 0.01
0.01
 < 0.01
49.8
Fluid loading > 4 ml/kg
Yes
No
SVV
45
21
14.4(10.7–19.4)
12.4(9.6–16.1)
11.7(8.6–15.7)
0.63
NA
54.0
Fluid loading > 4 ml/kg
Yes
No
PLR
55
16
22.6(17.0–30.2)
26.0(18.1–37.3)
13.0(7.3–23.2)
0.045
0.05
 < 0.01
53.0
Fluid loading > 4 ml/kg
Yes
No
EEOT
23
10
17.8(10.7–30.0)
24.4(13.3–44.8)
6.81(3.0–15.2)
 < 0.01
 < 0.01
 < 0.01
57
Fluid loading > 4 ml/kg
Yes
No
MFC
14
2
37.3(21.8–64.0)
35.7(22.0–58.1)
30.2(11.0–83.5)
0.09
NA
35.3
Fluid loading > 4 ml/kg
Yes
No
VTC
13
4
46.6(26.7–81.3)
30.1(17.2–52.5)
127.2(36.3–446.16)
0.06
NA
10.3
Hemodynamic variable to determine PLR response
Direct measurements (ABF, CO, CI, SV, SVI, VTI)
Surrogate
PLR
47
36
22.6(17.0–30.2)
32.3(21.7–48.1)
15.3(10.2–23.0)
 < 0.01
 < 0.01
 < 0.01
53.7
Hemodynamic variable to determine EEOT response
Direct measurements (ABF, CO, CI, SV, SVI, VTI)
Surrogate
EEOT
23
13
17.8(10.7–30.0)
36.7(19.7–68.2)
6.8(3.4–13.7)
 < 0.01
 < 0.01
 < 0.01
57.2
Lapse of time selected for EEOT
 ≤ 15 s
 > 15 – < 30 s
 ≥ 30 s
EEOT
22
11
3
17.8(10.7–30.0)
36.8(18.9–72.0)
10.1(4.6–22.0)
4.5(1.0–18.9)
 < 0.01
0.01
0.23
 < 0.01
59.3
DOR Diagnostic odd ratio, I2 Inconsistency. NA Not applicable, PPV Pulse pressure variation, PLR Passive leg raising, EEOT End-expiratory occlusion test, MFC Mini-fluid challenge, VTC Tidal volume challenge, ABF Aortic blood flow, CO Cardiac output, CI Cardiac index, SVI Stroke volume index, SV Stroke volume, VTI Velocity–time integral. Values are expressed as pooled data (95% confidence interval)
Table 3
Adjusted operative performance of the clinical variables for predictors of fluid responsiveness evaluated
Subgroup
Predictor evaluated
Number of studies
Unadjusted DOR (95%CI)
Adjusted DOR
(95% CI)
P value by subgroup analysis
P value by meta-regression
I2(%)
PEEP
EEOT
38
17.8(10.7–30.0)
DOR = 1.06 + 1.21 (cmH2O PEEP)
NA
 < 0.01
53.4
Norepinephrine dose ≥ 0.3 mcg/kg/min
Yes
No
PPV
25
10
16.6 (12.9 – 21.7)
14.1(8.5–23.4)
18.0(7.8–41.3)
0.63
NA
50.9
Norepinephrine dose ≥ 0.3 mcg/kg/min
Yes
No
SVV
8
5
14.4(10.7–19.4)
13.3(4.8–36.6)
29.4(7.8–111.2)
0.34
NA
60.6
Norepinephrine dose ≥ 0.3 mcg/kg/min
Yes
No
PLR
24
11
22.6(17.0–30.2)
49.9(27.6–90.1)
16.2(7.7–34.2)
0.02
0.02
 < 0.01
61.2
Norepinephrine dose ≥ 0.3 mcg/kg/min
Yes
No
EEOT
19
3
17.8(10.7–30.0)
58.7(28.6–120.4)
11.5(3.0–44.2)
0.03
0.04
 < 0.01
45.2
DOR Diagnostic odd ratio, I2 Inconsistency. PPV Pulse pressure variation, PEEP Positive end-expiratory pressure, SVV Stroke volume variations, EEOT End-expiratory occlusion test; PLR Passive leg raising. Values are expressed as pooled data (95% confidence interval)

Technical variables

The volume of fluid administered had a significant impact on the predictive performance of several hemodynamic variables, namely pulse pressure variation (PPV), passive leg raising (PLR), and the end-expiratory occlusion test (EEOT). When fluid loading exceeded 4 ml/kg, the predictive performance of such fluid responsiveness predictors increased, as evidenced by the increase in the diagnostic odds ratio (DOR). Conversely, when fluid doses were ≤ 4 ml/kg, the opposite trend was observed, resulting in a decrease in the DOR values for all three predictors (p < 0.05) (Table 2).
The hemodynamic variables used to determine the PLR/EEOT response were found to significantly influence their predictive performance. Direct macro-flow measurements such as aortic blood flow (ABF), cardiac output (CO) or cardiac index (CI), stroke volume (SV) or stroke volume index (SVI), and velocity–time integral (VTI) increased its predictive performance (Table 2). Conversely, using surrogates of CO led to a decrease in predictive performance for both PLR and EEOT. Moreover, the EEOT predictive performance was found to increase when the time lapse for the EEOT maneuver was ≤ 15 s (p < 0.01), while its predictive performance significantly decreased when the time lapse exceeded 30 s (p < 0.01) (Table 2).
The operative performance related to other variables evaluated is shown in the Additional file 1: Appendix (Table S11).

Clinical variables

As expected, progressively higher positive end-expiratory pressure (PEEP) values improved the ability of the end-expiratory occlusion test (EEOT) to predict fluid responsiveness. In fact, increasing PEEP by just 1.21 cmH2O led to a significant improvement in EEOT performance (p < 0.01) (Table 3).
Higher doses of norepinephrine (≥ 0.3 mcg/kg/min) were related to significant improvements in the performance of PLR and EEOT to predict fluid responsiveness, while lower doses had the opposite effect (Table 3). Nevertheless, norepinephrine dose was not related to significant changes in the performance of PPV and SVV (p > 0.05) (Table 3).
Additional analyses of the sources of variability are summarized in the Additional file 1: (Table S11).

Additional analysis

There was no threshold effect for any predictor (p > 0.05), as evaluated by both the rho correlation coefficient and the Moses–Shapiro–Littenberg test. The accuracy of PPV as a diagnostic measure was deemed moderately reliable because the results from the studies included lack precision and might not be applicable to all clinical settings. Conversely, the accuracy of other predictors was deemed highly reliable. Additional information on the GRADE assessment can be found in Appendix Table S12-Table S17 of the Additional file 1.

Sensitivity analysis

Sensitivity analysis did not retrieve significant changes in the operative performance of any of the fluid responsiveness predictors evaluated according to the methodological quality (QUADAS-2) (p > 0.05) (Table S18 of the Additional file 1). However, sensitivity analysis (Table 4) revealed several sources of heterogeneity (Table 4). Such sources of heterogeneity accounted for varying percentages of heterogeneity in each predictor. More details on the sensitivity analysis can be found in Additional file 1: Appendix Table S19.
Table 4
Sensitivity analysis of predictor of fluid responsiveness based on the reference standard used, type of patient, hemodynamic variable to determine PLR/EEOT response, device ued to measure PLR response and the number of patients included in each study
Risk of bias within studies
Predictor
Number of studies
Adjusted diagnostic odds ratios (95% CI)
P value by test for subgroup
I2 (%)
R2 (%)
Measurement method to assess excitation method
SVV
     
PAC
Esophageal Doppler
TTE
TEE
Impedance
PCA (LiDCO)
NC-PCA(ModelFlow)
NC-PCA(MostCare)
NC-PCA(PiCCO)
TPTD(PiCCO)
PAC(Vigilance)
NC-PCA(Vigileo)
 
4
8
1
3
6
1
2
1
5
16
2
20
17.9(6.7–47.9)
6.0(3.2–11.4)
4.6(1.1–19.5)
4.6(1.5–13.9)
79.9(34.1–187.9)
697.0(22.8–21,293.6)
34.6(4.3–284.1)
5.06(1.3–20.5)
14.0(6.5–30.1)
9.2(5.6–15.2)
8.9(2.2–36.4)
20.0(12.3–32.5)
0.02
29.1
61.8
Device used to measure PLR response
PLR
     
C-TD
Capnography
Doppler
Esophageal Doppler
TTE
TTE/PCA (PiCCO)
Bioimpedance technique
Others
C-PCA(PiCCO)
Arterial pressure
Photoplethysmography technology
Abdominal ultrasonography
NC-PCA(Vigileo)
 
1
2
5
2
24
2
2
3
22
12
1
4
3
10.1(1.8–55.7)
118.9(15.9–887.2)
50.4(20.7–122.7)
169.7(25.9–1111.88)
22.7(14.8–34.7)
66.8(28.9–154.7)
83.4(10.7–652.7)
21.3(6.3–72.4)
17.8(10.8–29.2)
6.4(4.10–10.0)
38.7(7.2–207.2)
16.1(4.8–54.3)
73.1(16.4–325.6)
 < 0.01
21.4
74.7
Measurement method to assess excitation method
PLR
     
Esophageal Doppler
TTE
TTE/TPTD(PiCCO)
Bioimpedance technique
C-PCA(PiCCO)
TPTD(PiCCO)
Ultrasonic cardiac output monitor
PAC (Vigilance)
NC-PCA(Vigileo)
 
6
31
2
2
12
21
2
1
6
30.2(11.2–81.1)
24.4(15.9–37.5)
67.0(21.7–206.3)
88.1(10.5–742.46)
28.3(13.1–61.2)
13.6(8.0–23.1)
63.0(13.1–301.4)
10.1(1.4–75.5)
8.5(4.0–18.2)
0.02
38.9
38.9
Measurement method to assess excitation method
EEOT
     
Esophageal Doppler
TEE
TTE
NC-PCA(MostCare)
C-PCA(PiCCO)
TPTD(PiCCO)
NC-PCA(Pulsioflex/ProAQT)
NC-PCA(Vigileo)
 
2
3
2
4
1
16
4
4
8.3(1.8–37.7)
11.2(3.5–36.3)
19.0(3.7–96.4)
15.0(5.2–43.2)
96.2(11.1–831.4)
64.9(30.0–140.3)
6.2(2.1–18.3)
3.1(1.1–8.7)
0.01
43.2
59.3
Clinical setting
EEOT
     
Cardiovascular
Neurologic
Neurosurgical
Surgical
Septic
 
3
2
4
10
17
11.1(3.6–34.8)
18.5(3.8–90.3)
20.5(6.2–68.2)
5.0(2.71–9.2)
67.2(32.9–137.4)
0.01
42.1
63.5
Hemodynamic variable to determine EEOT response
ETCO2
FTC
CI
SVI
Others
PI
PP
Cardiac Peak velocity
PPV
SV
VTI
EEOT
1
1
13
3
1
2
3
3
2
4
3
6.1(1.4–25.7)
15.0(2.3–99.6)
105.5(50.6–219.2)
9.1(4.6–18.4)
8.4(1.4–48.8)
4.7(1.8–12.4)
4.9(2.3–10.4)
8.1(3.3–19.4)
4.7(2.0–10.6)
4.2(2.0–10.6)
83.9(26.6–264.3)
0.01
11.4
92.9
I2 Inconsistency, R2 Amounts of heterogeneity, C-TD, continuous thermodilution, C-PCA, calibrated pulse contour analysis, CO Cardiac output, CI Cardiac index, EEOT End-expiratory occlusion test, NC-PCA Non-calibrated pulse contour analysis, PAC Pulmonary artery catheter, PLR Passive leg raising, PPV Pulse pressure variation, SV Stroke volume; SVI Stroke volume index, SVV Stroke volume variation, TEE Transesophageal echocardiography, TPTD Transpulmonary thermodilution, TTE Transthoracic echocardiography, VTI Velocity time integral

Discussion

This systematic review and meta-analysis highlights the impact of some technical and clinical variables on the operative performance of predictors of fluid responsiveness commonly used in clinical practice. A fluid loading > 4 ml/kg, the type of hemodynamic variable used to assess the response to PLR/EEOT, the apneic time during the EEOT maneuver, the PEEP level used during EEOT, and the doses of norepinephrine used at the FR assessment were identified as the main technical/clinical variables influencing the operative performance of commonly used fluid responsiveness predictors. Consequently, such variables should be carefully considered when making individual decisions.
Previous meta-analyses have assessed the value of fluid responsiveness predictors in various clinical scenarios, demonstrating their overall good performance [518]. However, heterogeneity of the studies included in such meta-analyses hinders their applicability to clinical practice. To address this issue, subgroup analysis and meta-regression are recommended to determine sources of heterogeneity and assess changes in operative performance within each subgroup [26]. Several meta-analyses conducted subgroup analyses and recognized the impact of some clinical variables on operative performance to predict fluid responsiveness [5, 6, 1518]. Unlike some authors using bivariate analysis to assess operative performance [16, 17], we evaluated DORs as a summary measure, and we employed meta-regression to examine quantitative variables.
The operative performance of PPV, PLR, and EEOT was significantly improved in cases in which fluid loading was > 4 mL/kg, which agrees with previous observations showing that increases in fluid loading from 1 to 4 mL/kg enhanced the rate of fluid responders from 20 to 65% [27]. Nevertheless, others have not found significant variations in the performance of EEOT caused by different volumes of fluid loading [18], while its influence on SVV and PLR performance is difficult to evaluate because of the high heterogeneity of the studies included [17].
Direct estimates of macrovascular blood flow, such as CO/CI, ABF, SV/SVI, and VTI, are related to significantly better operative performance of PLR/EEOT. In contrast, using CO surrogates such as pulse pressure (PP), SVV, and PPV led to a decrease in operative performance. This phenomenon may be due to the relationship between CO surrogates and other physiological variables [28], such as PP, which is linked to arterial compliance, impedance, and wave reflection [29]. These findings align with those of previously published studies [30].
The duration of the respiratory hold constitutes a critical technical variable that demands careful consideration during the execution of this test. Notably, the operative performance displays an augmentation when the EEOT duration is ≤ 15 s, while a decline is observed when it extends to ≥ 30 s. This trend might be attributed to the fact that the maximal alteration in venous return and cardiac output typically materializes within the initial 15 s, with subsequent reductions occurring due to the finite nature of this change [31]. Moreover, it is imperative to acknowledge that a persistent reduction in pleural pressure has the potential to elevate left ventricular afterload [32], especially in individuals with myocardial dysfunction [33]. This phenomenon, in turn, could lead to a decrease in stroke volume when the EEOT maneuver surpasses the 30-s mark. While this finding aligns with physiological plausibility, it is worth noting that, to the best of our knowledge, no clinical trials or other meta-analyses have reported a substantial alteration in the operative performance of EEOT based on its duration [15, 18]. We attribute this variance to three key factors. First, our evaluation encompassed three distinct subgroups, whereas the referenced meta-analyses examined two subgroups. Second, two clinical studies that employed a respiratory hold duration of ≥ 30 s were excluded from the mentioned meta-analyses [34, 35]. Last, it is noteworthy that these studies reported a notably low operative performance for EEOT [34, 35].
Although some authors have suggested that including the volume of the MFC within the fluid loading might change its operative performance [36], our meta-analysis did not confirm such data.
Our findings reported a positive relationship between EEOT operative performance and PEEP, which could be explained for two reasons. First, increasing PEEP could improve pulmonary compliance (by alveolar recruitment) due to an increase in cyclic changes in intrathoracic pressure induced by EEOT, thus increasing its operative performance [37]. Second, the use of a high PEEP increases right ventricular afterload and right atrial pressure, which would lead to a decrease in venous return, finally increasing preload dependence and increasing its operative performance. Our findings did not agree with the results reported by Silva et al. [37], who did not find a relationship between EEOT operative performance and PEEP. This difference could be explained by two reasons. First, they only evaluated patients with acute respiratory distress syndrome (ARDS), while we also included studies that evaluated patients without ARDS. Second, they did not find that increasing PEEP changed the driving pressure (plateau pressure – PEEP); therefore, the changes in intrathoracic pressure induced by such an increase were not achieved, and the preload dependence did not change. Silva et al. concluded that EEOT operative performance remains reliable when PEEP is increased in ARDS patients, but the EEOT performance could change in patients in whom driving pressure increases; however, we did not find that driving pressure changes the EEOT operative performance (see Supplement Material Appendix; Table S11); therefore, the PEEP itself is a determinant of the hemodynamic effects of EEOT. Other meta-analyses have not found this finding [15, 18, 38], which could be due to our study assessing PEEP as a continuous variable (by meta-regression), while other meta-analyses evaluated PEEP as a categorical variable (by bivariate analysis). Finally, we did not find that Vt changes the EEOT operative performance (see Additional file 1: Appendix; Table S11).
Our data also suggest that doses of norepinephrine > 0.3 mcg/kg/min result in significant increases in the operative performance of PLR and EEOT. Previous studies have described that using norepinephrine is associated with fluid responsiveness [39]. The likelihood of exhibiting a positive fluid response is intricately linked to factors such as the mean systemic filling pressure (MSFP) and the interplay between stressed and unstressed volumes. In the context of vasoplegic states, the unstressed volume tends to rise, while both the stressed volume and MSFP decline. Consequently, there is a decrease in preload and stroke volume. Interestingly, these states may not manifest a fluid response since the introduction of fluid merely results in an elevated unstressed volume, lacking a corresponding rise in MSFP. As a result, the false negative rate of certain predictors may escalate, subsequently diminishing their operative performance during vasoplegic conditions [40]. The introduction of norepinephrine contributes to an increase in stressed volume and MSFP. This leads to a boost in venous return and stroke volume following a fluid load [41]. Remarkably, the relationship between operative performance and norepinephrine use has not been previously documented, as per our knowledge.
Our meta-analysis has several limitations. First, while the diagnostic odds ratio (DOR) summarizes the relationship between sensitivity and specificity, it does not indicate the direction of the relationship (which may vary among different predictors), even at similar DOR values [42]. Second, some special clinical conditions were not evaluated (i.e., patients with intra-abdominal hypertension), which limits the generalizability of our results. Third, a majority of predictors exhibited a moderate level of heterogeneity. However, our analysis pinpointed various sources of this heterogeneity, including disparities in the measurement methods used to evaluate the excitation method. Fourth, it is noteworthy that we did not explore other factors that could influence fluid responsiveness, such as the impact of medications such as analgosedation. These medications can potentially affect the autonomic nervous system, thereby potentially modifying the sympathetic response to fluid loading. It is important to note that the use of such medications was infrequently reported in most of the included studies, adding complexity to their potential impact on the observed outcomes. Finally, we did not investigate the connection between fluid responsiveness and tissue perfusion, a clinical aspect that we consider of utmost importance.

Conclusions

Based on our findings, we recommend conducting a PLR/EEOT test with direct CO measurement. For the EEOT, the respiratory hold should be limited to less than 15 s. Physicians should be aware that higher positive end-expiratory pressure (PEEP) levels enhance the performance of EEOT. Additionally, the use of norepinephrine has been observed to enhance the operative performance of external fluid loading maneuvers, such as PLR and EEOT. Finally, when performing a fluid challenge, a volume of less than 4 ml/kg is suggested.

Acknowledgements

We don´t have acknowledgments.
Author contributions
Design: all authors. Performed the literature review: J.I.A. S, J.D.C.R. Acquisition of data: J.I.A. S, J.D.C.R. Statistical analysis: J.I.A.S. Interpretation of data: All authors. Wrote the manuscript: All authors.

Declarations

Does not apply. The author(s) declare that they do not have a conflicting interest. Additionally, the author(s) received no financial support for the research, authorship, and/or publication of this manuscript.
Does not apply.

Competing interests

The author’s declare that they do not have a competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Anhänge
Literatur
1.
Zurück zum Zitat Cecconi M, Parsons AK, Rhodes A. What is a fluid challenge? Curr Opin Crit Care. 2011;17:290–5.PubMed Cecconi M, Parsons AK, Rhodes A. What is a fluid challenge? Curr Opin Crit Care. 2011;17:290–5.PubMed
2.
Zurück zum Zitat Alvarado Sánchez JI, Amaya Zúñiga WF, Monge García MI. Predictors to intravenous fluid responsiveness. J Intensive Care Med. 2018;33:227–40.PubMed Alvarado Sánchez JI, Amaya Zúñiga WF, Monge García MI. Predictors to intravenous fluid responsiveness. J Intensive Care Med. 2018;33:227–40.PubMed
3.
Zurück zum Zitat Sakr Y, Rubatto Birri PN, Kotfis K, Nanchal R, Shah B, Kluge S, et al. Higher fluid balance increases the risk of death from sepsis: results from a large international audit∗. Crit Care Med. 2017;45:386–94.PubMed Sakr Y, Rubatto Birri PN, Kotfis K, Nanchal R, Shah B, Kluge S, et al. Higher fluid balance increases the risk of death from sepsis: results from a large international audit∗. Crit Care Med. 2017;45:386–94.PubMed
4.
Zurück zum Zitat Evans L, Rhodes A, Alhazzani W, Antonelli M, Coopersmith CM, French C, et al. Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021, interpretation and expectation. Crit Care Med. 2021;33:1159–64. Evans L, Rhodes A, Alhazzani W, Antonelli M, Coopersmith CM, French C, et al. Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021, interpretation and expectation. Crit Care Med. 2021;33:1159–64.
5.
Zurück zum Zitat Wang X, Liu S, Gao J, Zhang Y, Huang T. Does tidal volume challenge improve the feasibility of pulse pressure variation in patients mechanically ventilated at low tidal volumes? A systematic review and meta-analysis. Crit Care. 2023;27:45.PubMedPubMedCentral Wang X, Liu S, Gao J, Zhang Y, Huang T. Does tidal volume challenge improve the feasibility of pulse pressure variation in patients mechanically ventilated at low tidal volumes? A systematic review and meta-analysis. Crit Care. 2023;27:45.PubMedPubMedCentral
6.
Zurück zum Zitat Huan S, Dai J, Song S, Zhu G, Ji Y, Yin G. Stroke volume variation for predicting responsiveness to fluid therapy in patients undergoing cardiac and thoracic surgery: a systematic review and meta-analysis. BMJ Open. 2022;12(5):e051112.PubMedPubMedCentral Huan S, Dai J, Song S, Zhu G, Ji Y, Yin G. Stroke volume variation for predicting responsiveness to fluid therapy in patients undergoing cardiac and thoracic surgery: a systematic review and meta-analysis. BMJ Open. 2022;12(5):e051112.PubMedPubMedCentral
7.
Zurück zum Zitat Huang H, Wu C, Shen Q, Fang Y, Xu H. Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis. Crit Care. 2022;26:20.PubMedPubMedCentral Huang H, Wu C, Shen Q, Fang Y, Xu H. Value of variation of end-tidal carbon dioxide for predicting fluid responsiveness during the passive leg raising test in patients with mechanical ventilation: a systematic review and meta-analysis. Crit Care. 2022;26:20.PubMedPubMedCentral
8.
Zurück zum Zitat Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.PubMed Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.PubMed
9.
Zurück zum Zitat Cavallaro F, Sandroni C, Marano C, la Torre G, Mannocci A, de Waure C, et al. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med. 2010;36:1475–83.PubMed Cavallaro F, Sandroni C, Marano C, la Torre G, Mannocci A, de Waure C, et al. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med. 2010;36:1475–83.PubMed
10.
Zurück zum Zitat Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.PubMed Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.PubMed
11.
Zurück zum Zitat Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014;18:650.PubMedPubMedCentral Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014;18:650.PubMedPubMedCentral
12.
Zurück zum Zitat Hong J-Q, He H-F, Chen Z-Y, Du Z-S, Liu W-F, Weng P-Q, et al. Comparison of stroke volume variation with pulse pressure variation as a diagnostic indicator of fluid responsiveness in mechanically ventilated critically ill patients. Saudi Med J. 2014;35:261–8.PubMed Hong J-Q, He H-F, Chen Z-Y, Du Z-S, Liu W-F, Weng P-Q, et al. Comparison of stroke volume variation with pulse pressure variation as a diagnostic indicator of fluid responsiveness in mechanically ventilated critically ill patients. Saudi Med J. 2014;35:261–8.PubMed
13.
Zurück zum Zitat Chaves RC, Corrêa TD, Neto AS, Bravim BD, Cordioli RL, Moreira FT, Timenetsky KT, de Assunção MS. Assessment of fluid responsiveness in spontaneously breathing patients: a systematic review of literature. Ann Intensive Care. 2018;8(1):1. Chaves RC, Corrêa TD, Neto AS, Bravim BD, Cordioli RL, Moreira FT, Timenetsky KT, de Assunção MS. Assessment of fluid responsiveness in spontaneously breathing patients: a systematic review of literature. Ann Intensive Care. 2018;8(1):1.
14.
Zurück zum Zitat Messina A, Dell’Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, et al. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Crit Care. 2019;23:264.PubMedPubMedCentral Messina A, Dell’Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, et al. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Crit Care. 2019;23:264.PubMedPubMedCentral
15.
Zurück zum Zitat Gavelli F, Shi R, Teboul J-L, Monnet X. Does the end-expiratory occlusion test predict preload responsiveness? A systematic review and meta-analysis. Ann Intensive Care. 2020;10:1692. Gavelli F, Shi R, Teboul J-L, Monnet X. Does the end-expiratory occlusion test predict preload responsiveness? A systematic review and meta-analysis. Ann Intensive Care. 2020;10:1692.
16.
Zurück zum Zitat Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, Ospina-Tascón GA, Cruz Martínez LE. Use of pulse pressure variation as predictor of fluid responsiveness in patients ventilated with low tidal volume: a systematic review and meta-analysis. Clin Med Insights Circ Respir Pulm Med. 2020;14:1–10. Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, Ospina-Tascón GA, Cruz Martínez LE. Use of pulse pressure variation as predictor of fluid responsiveness in patients ventilated with low tidal volume: a systematic review and meta-analysis. Clin Med Insights Circ Respir Pulm Med. 2020;14:1–10.
17.
Zurück zum Zitat Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, Amaya Zuñiga WF, Ospina-Tascón GA, Cruz Martínez LE. Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis. Ann Intensive Care. 2021;11:28.PubMedPubMedCentral Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, Amaya Zuñiga WF, Ospina-Tascón GA, Cruz Martínez LE. Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis. Ann Intensive Care. 2021;11:28.PubMedPubMedCentral
18.
Zurück zum Zitat Si X, Song X, Lin Q, Nie Y, Zhang G, Xu H, et al. Does end-expiratory occlusion test predict fluid responsiveness in mechanically ventilated patients? A systematic review and meta-analysis. Shock. 2020;54:751–60.PubMed Si X, Song X, Lin Q, Nie Y, Zhang G, Xu H, et al. Does end-expiratory occlusion test predict fluid responsiveness in mechanically ventilated patients? A systematic review and meta-analysis. Shock. 2020;54:751–60.PubMed
19.
Zurück zum Zitat Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JPA, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 2009;62:e1-34.PubMed Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JPA, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 2009;62:e1-34.PubMed
20.
Zurück zum Zitat Whiting PF, Rutjes AWS, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155:529–36.PubMed Whiting PF, Rutjes AWS, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155:529–36.PubMed
21.
Zurück zum Zitat Fischer JE, Bachmann LM, Jaeschke R. A readers’ guide to the interpretation of diagnostic test properties: clinical example of sepsis. Intensive Care Med. 2003;29:1043–51.PubMed Fischer JE, Bachmann LM, Jaeschke R. A readers’ guide to the interpretation of diagnostic test properties: clinical example of sepsis. Intensive Care Med. 2003;29:1043–51.PubMed
22.
Zurück zum Zitat Egger M, Smith GD, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997;315:629–34.PubMedPubMedCentral Egger M, Smith GD, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997;315:629–34.PubMedPubMedCentral
23.
Zurück zum Zitat Duval S, Tweedie R. Trim and fill: a simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis. Biometrics. 2000;56:455–63.PubMed Duval S, Tweedie R. Trim and fill: a simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis. Biometrics. 2000;56:455–63.PubMed
24.
Zurück zum Zitat Yang B, Mustafa RA, Bossuyt PM, Brozek J, Hultcrantz M, Leeflang MMG, et al. GRADE guidance: 31 assessing the certainty across a body of evidence for comparative test accuracy. J Clin Epidemiol. 2021;136:146–56.PubMed Yang B, Mustafa RA, Bossuyt PM, Brozek J, Hultcrantz M, Leeflang MMG, et al. GRADE guidance: 31 assessing the certainty across a body of evidence for comparative test accuracy. J Clin Epidemiol. 2021;136:146–56.PubMed
25.
Zurück zum Zitat Moses LE, Shapiro D, Littenberg B. Combining independent studies of a diagnostic test into a summary roc curve: data-analytic approaches and some additional considerations. Stat Med. 1993;12:1293–316.PubMed Moses LE, Shapiro D, Littenberg B. Combining independent studies of a diagnostic test into a summary roc curve: data-analytic approaches and some additional considerations. Stat Med. 1993;12:1293–316.PubMed
26.
Zurück zum Zitat Schwarzer G, Carpenter JR, Rücker G. Heterogeneity and Meta-Regression. Meta-Analysis with R, 1st edn Springer, Switzerland. 2015; 85–104. Schwarzer G, Carpenter JR, Rücker G. Heterogeneity and Meta-Regression. Meta-Analysis with R, 1st edn Springer, Switzerland. 2015; 85–104.
27.
Zurück zum Zitat Aya HD, Ster IC, Fletcher N, Grounds RM, Rhodes A, Cecconi M. Pharmacodynamic analysis of a fluid challenge. Crit Care Med. 2016;44:880–91.PubMed Aya HD, Ster IC, Fletcher N, Grounds RM, Rhodes A, Cecconi M. Pharmacodynamic analysis of a fluid challenge. Crit Care Med. 2016;44:880–91.PubMed
28.
Zurück zum Zitat West JB. State of the art: ventilation-perfusion relationships. Am Rev Respir Dis. 1977;116:919–43.PubMed West JB. State of the art: ventilation-perfusion relationships. Am Rev Respir Dis. 1977;116:919–43.PubMed
29.
Zurück zum Zitat Sunagawa K. Left ventricular interaction with arterial load studied in isolated canine ventricle. Am J Physiol. 1983;5:H773–80. Sunagawa K. Left ventricular interaction with arterial load studied in isolated canine ventricle. Am J Physiol. 1983;5:H773–80.
30.
Zurück zum Zitat Monnet X, Marik P, Teboul JL. Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Med. 2016;42:1935–47.PubMed Monnet X, Marik P, Teboul JL. Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Med. 2016;42:1935–47.PubMed
31.
Zurück zum Zitat Gavelli F, Teboul J-L, Monnet X. The end-expiratory occlusion test: please, let me hold your breath! Crit Care. 2019;23:274.PubMedPubMedCentral Gavelli F, Teboul J-L, Monnet X. The end-expiratory occlusion test: please, let me hold your breath! Crit Care. 2019;23:274.PubMedPubMedCentral
32.
Zurück zum Zitat Mahmood SS, Pinsky MR. Heart-lung interactions during mechanical ventilation: the basics. Ann Transl Med. 2018;6:349–349.PubMedPubMedCentral Mahmood SS, Pinsky MR. Heart-lung interactions during mechanical ventilation: the basics. Ann Transl Med. 2018;6:349–349.PubMedPubMedCentral
33.
Zurück zum Zitat Pinsky MR. Cardiovascular issues in respiratory care. Chest. 2005;128:592S-597S.PubMed Pinsky MR. Cardiovascular issues in respiratory care. Chest. 2005;128:592S-597S.PubMed
34.
Zurück zum Zitat Lizuka Y, Sanui M, Otsuka Y, Yoshinaga K, Nakatomi T, Lefor AK. Changes in peripheral perfusion index during intraoperative end-expiratory occlusion tests do not predict the response to fluid administration in patients undergoing lung protective ventilation. J Anesth. 2021;35:837–43. Lizuka Y, Sanui M, Otsuka Y, Yoshinaga K, Nakatomi T, Lefor AK. Changes in peripheral perfusion index during intraoperative end-expiratory occlusion tests do not predict the response to fluid administration in patients undergoing lung protective ventilation. J Anesth. 2021;35:837–43.
35.
Zurück zum Zitat Messina A, Lionetti G, Foti L, Bellotti E, Marcomini N, Cammarota G, et al. Mini fluid challenge and end-expiratory occlusion test to assess fluid responsiveness in the operating room (MANEUVER study): a multicentre cohort study. Eur J Anaesthesiol. 2021;38:422–31.PubMed Messina A, Lionetti G, Foti L, Bellotti E, Marcomini N, Cammarota G, et al. Mini fluid challenge and end-expiratory occlusion test to assess fluid responsiveness in the operating room (MANEUVER study): a multicentre cohort study. Eur J Anaesthesiol. 2021;38:422–31.PubMed
36.
Zurück zum Zitat Enevoldsen J, Scheeren TWL, Berg JM, Vistisen ST. Existing fluid responsiveness studies using the mini-fluid challenge may be misleading: methodological considerations and simulations. Acta Anaesthesiol Scand. 2022;66:17–24.PubMed Enevoldsen J, Scheeren TWL, Berg JM, Vistisen ST. Existing fluid responsiveness studies using the mini-fluid challenge may be misleading: methodological considerations and simulations. Acta Anaesthesiol Scand. 2022;66:17–24.PubMed
37.
Zurück zum Zitat Silva S, Jozwiak M, Teboul J-L, Richard C, Monnet X, Persichini R. End-expiratory occlusion test predicts preload responsiveness independently of positive end-expiratory pressure during acute respiratory distress syndrome. Crit Care Med. 2013;41:1692–701.PubMed Silva S, Jozwiak M, Teboul J-L, Richard C, Monnet X, Persichini R. End-expiratory occlusion test predicts preload responsiveness independently of positive end-expiratory pressure during acute respiratory distress syndrome. Crit Care Med. 2013;41:1692–701.PubMed
38.
Zurück zum Zitat Messina A, Dell’Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, Saderi L, Sotgiu G, Antonelli M, Cecconi M. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Crit Care. 2019;23:1–6. Messina A, Dell’Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, Saderi L, Sotgiu G, Antonelli M, Cecconi M. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Crit Care. 2019;23:1–6.
39.
Zurück zum Zitat Nguyen M, Mallat J, Marc J, Abou-Arab O, Bouhemad B, Guinot PG. Arterial load and norepinephrine are associated with the response of the cardiovascular system to fluid expansion. Front Physiol. 2021;4(12):707832. Nguyen M, Mallat J, Marc J, Abou-Arab O, Bouhemad B, Guinot PG. Arterial load and norepinephrine are associated with the response of the cardiovascular system to fluid expansion. Front Physiol. 2021;4(12):707832.
40.
Zurück zum Zitat Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, Ospina Tascon GA, Monge Garcia MI, Ruiz Narvaez GA, et al. Changes of operative performance of pulse pressure variation as a predictor of fluid responsiveness in endotoxin shock. Sci Rep. 2022;12:1–8. Alvarado Sánchez JI, Caicedo Ruiz JD, Diaztagle Fernández JJ, Ospina Tascon GA, Monge Garcia MI, Ruiz Narvaez GA, et al. Changes of operative performance of pulse pressure variation as a predictor of fluid responsiveness in endotoxin shock. Sci Rep. 2022;12:1–8.
41.
Zurück zum Zitat Monnet X, Jabot J, Maizel J, Richard C, Teboul JLL. Norepinephrine increases cardiac preload and reduces preload dependency assessed by passive leg raising in septic shock patients. Crit Care Med. 2011;39:689–94.PubMed Monnet X, Jabot J, Maizel J, Richard C, Teboul JLL. Norepinephrine increases cardiac preload and reduces preload dependency assessed by passive leg raising in septic shock patients. Crit Care Med. 2011;39:689–94.PubMed
42.
Zurück zum Zitat Glas AS, Lijmer JG, Prins MH, Bonsel GJ, Bossuyt PMM. The diagnostic odds ratio: a single indicator of test performance. J Clin Epidemiol. 2003;56:1129–35.PubMed Glas AS, Lijmer JG, Prins MH, Bonsel GJ, Bossuyt PMM. The diagnostic odds ratio: a single indicator of test performance. J Clin Epidemiol. 2003;56:1129–35.PubMed
Metadaten
Titel
Variables influencing the prediction of fluid responsiveness: a systematic review and meta-analysis
verfasst von
Jorge Iván Alvarado Sánchez
Juan Daniel Caicedo Ruiz
Juan José Diaztagle Fernández
Luís Eduardo Cruz Martínez
Fredy Leonardo Carreño Hernández
Carlos Andrés Santacruz Herrera
Gustavo Adolfo Ospina-Tascón
Publikationsdatum
01.12.2023
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 1/2023
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-023-04629-w

Weitere Artikel der Ausgabe 1/2023

Critical Care 1/2023 Zur Ausgabe

Mit dem Seitenschneider gegen das Reißverschluss-Malheur

03.06.2024 Urologische Notfallmedizin Nachrichten

Wer ihn je erlebt hat, wird ihn nicht vergessen: den Schmerz, den die beim Öffnen oder Schließen des Reißverschlusses am Hosenschlitz eingeklemmte Haut am Penis oder Skrotum verursacht. Eine neue Methode für rasche Abhilfe hat ein US-Team getestet.

Blutdrucksenkung schon im Rettungswagen bei akutem Schlaganfall?

31.05.2024 Apoplex Nachrichten

Der optimale Ansatz für die Blutdruckkontrolle bei Patientinnen und Patienten mit akutem Schlaganfall ist noch nicht gefunden. Ob sich eine frühzeitige Therapie der Hypertonie noch während des Transports in die Klinik lohnt, hat jetzt eine Studie aus China untersucht.

Ähnliche Überlebensraten nach Reanimation während des Transports bzw. vor Ort

29.05.2024 Reanimation im Kindesalter Nachrichten

Laut einer Studie aus den USA und Kanada scheint es bei der Reanimation von Kindern außerhalb einer Klinik keinen Unterschied für das Überleben zu machen, ob die Wiederbelebungsmaßnahmen während des Transports in die Klinik stattfinden oder vor Ort ausgeführt werden. Jedoch gibt es dabei einige Einschränkungen und eine wichtige Ausnahme.

Nicht Creutzfeldt Jakob, sondern Abführtee-Vergiftung

29.05.2024 Hyponatriämie Nachrichten

Eine ältere Frau trinkt regelmäßig Sennesblättertee gegen ihre Verstopfung. Der scheint plötzlich gut zu wirken. Auf Durchfall und Erbrechen folgt allerdings eine Hyponatriämie. Nach deren Korrektur kommt es plötzlich zu progredienten Kognitions- und Verhaltensstörungen.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.