Objectives

Reconstruction of a three-dimensional jaw position determined by a bite recording is an important aspect of prosthetic therapy. Different materials are used for this purpose. In the dental technical workflow, recordings are used to mount a lower jaw cast in a patient-like spatial position relative to the upper jaw cast. We evaluated the accuracy of positioning under the influence of different jaw positions and materials.

Materials and methods

In an experimental setup, comprising an articulator, a pair of metal casts, and an optoelectronic measurement system, the spatial position of the incisal point and two condylar points were measured. To evaluate the accuracy of repeated repositioning of casts in the technical workflow, 324 measurements were taken from 108 recordings, consisting of silicone bite-stops made of addition curing silicone with 95 shore hardness, acrylic wafers, and wax recordings. The recordings were obtained in four jaw relations differing in vertical and protrusive components.

Results

Of the three materials/material combinations examined, silicone showed the most consistent results across all measurements, followed by the acrylic wafer system, and then wax recordings. Generally, recordings with smaller gaps between the jaws and no protrusive components showed greater deviations compared to jaw positions with greater protrusion and higher vertical dimensions.

Conclusions and clinical relevance

To achieve reliable model mounting with high accuracy, recordings should include the use of a frontal jig and four small recording platelets made of silicone, especially if only a slight elevation of the vertical dimension is needed.
Literatur
1.
Zurück zum Zitat Türp JC, Schindler HJ, Rodiger O, Smeekens S, Marinello CP (2006) [Vertical and horizontal jaw relations in reconstructive dentistry. A critical review]. Schweiz Monatsschr Zahnmed 116:403–417PubMed Türp JC, Schindler HJ, Rodiger O, Smeekens S, Marinello CP (2006) [Vertical and horizontal jaw relations in reconstructive dentistry. A critical review]. Schweiz Monatsschr Zahnmed 116:403–417PubMed
2.
Zurück zum Zitat Keshvad A, Winstanley RB (2001) An appraisal of the literature on centric relation. Part III. J Oral Rehabil 28:55–63CrossRefPubMed Keshvad A, Winstanley RB (2001) An appraisal of the literature on centric relation. Part III. J Oral Rehabil 28:55–63CrossRefPubMed
3.
Zurück zum Zitat Weffort SY, de Fantini SM (2010) Condylar displacement between centric relation and maximum intercuspation in symptomatic and asymptomatic individuals. Angle Orthod 80:835–842CrossRefPubMedPubMedCentral Weffort SY, de Fantini SM (2010) Condylar displacement between centric relation and maximum intercuspation in symptomatic and asymptomatic individuals. Angle Orthod 80:835–842CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Böhm A, Rammelberg P, May H-C, Pho Duc J-M, Pospiech P, Gernet W (1995) Direkte dreidimensionale elektronische Kondylenpositionsanalyse zur Bestimmung von RKP-IKP-Diskrepanzen. Dtsch Zahnärztl Z 50:35–39 Böhm A, Rammelberg P, May H-C, Pho Duc J-M, Pospiech P, Gernet W (1995) Direkte dreidimensionale elektronische Kondylenpositionsanalyse zur Bestimmung von RKP-IKP-Diskrepanzen. Dtsch Zahnärztl Z 50:35–39
5.
Zurück zum Zitat Utz KH, Duvenbeck H, Oettershagen K (1990) Distanz zwischen terminaler Scharnierachsenposition und Interkuspidationsposition im Kiefergelenkbereich. Schweiz Monatsschr Zahnmed 100:42–4s9PubMed Utz KH, Duvenbeck H, Oettershagen K (1990) Distanz zwischen terminaler Scharnierachsenposition und Interkuspidationsposition im Kiefergelenkbereich. Schweiz Monatsschr Zahnmed 100:42–4s9PubMed
6.
Zurück zum Zitat Kantor ME, Silverman SI, Garfinkel L (1972) Centric-relation recording techniques–a comparative investigation. J Prosthet Dent 28:593–600CrossRefPubMed Kantor ME, Silverman SI, Garfinkel L (1972) Centric-relation recording techniques–a comparative investigation. J Prosthet Dent 28:593–600CrossRefPubMed
7.
Zurück zum Zitat Lundeen HC (1974) Centric relation records: the effect of muscle action. J Prosthet Dent 31:244–253CrossRefPubMed Lundeen HC (1974) Centric relation records: the effect of muscle action. J Prosthet Dent 31:244–253CrossRefPubMed
8.
Zurück zum Zitat Smith HF Jr. (1975) A comparison of empirical centric relation records with location of terminal hinge axis and apex of the gothic arch tracing. J Prosthet Dent 33:511–520CrossRefPubMed Smith HF Jr. (1975) A comparison of empirical centric relation records with location of terminal hinge axis and apex of the gothic arch tracing. J Prosthet Dent 33:511–520CrossRefPubMed
9.
Zurück zum Zitat Simon RL, Nicholls JI (1980) Variability of passively recorded centric relation. J Prosthet Dent 44:21–26CrossRefPubMed Simon RL, Nicholls JI (1980) Variability of passively recorded centric relation. J Prosthet Dent 44:21–26CrossRefPubMed
10.
11.
Zurück zum Zitat Sindledecker L (1981) Effect of different centric relation registrations on the pantographic representation of centric relation. J Prosthet Dent 46:271–279CrossRefPubMed Sindledecker L (1981) Effect of different centric relation registrations on the pantographic representation of centric relation. J Prosthet Dent 46:271–279CrossRefPubMed
12.
Zurück zum Zitat Piehslinger E, Celar A, Celar R, Jager W, Slavicek R (1993) Reproducibility of the condylar reference position. J Orofac Pain 7:68–75PubMed Piehslinger E, Celar A, Celar R, Jager W, Slavicek R (1993) Reproducibility of the condylar reference position. J Orofac Pain 7:68–75PubMed
13.
Zurück zum Zitat Utz KH, Muller F, Luckerath W, Fuss E, Koeck B (2002) Accuracy of check-bite registration and centric condylar position. J Oral Rehabil 29:458–466CrossRefPubMed Utz KH, Muller F, Luckerath W, Fuss E, Koeck B (2002) Accuracy of check-bite registration and centric condylar position. J Oral Rehabil 29:458–466CrossRefPubMed
14.
Zurück zum Zitat Woda A, Pionchon P, Palla S (2001) Regulation of mandibular postures: mechanisms and clinical implications. Crit Rev Oral Biol Med 12:166–178CrossRefPubMed Woda A, Pionchon P, Palla S (2001) Regulation of mandibular postures: mechanisms and clinical implications. Crit Rev Oral Biol Med 12:166–178CrossRefPubMed
16.
Zurück zum Zitat Hellmann D, Becker G, Fingerhut C, Schmitter M, Rammelsberg P, Schindler HJ (2014) Methods of determining centric relation: a comparative study. J Craniomandib Function 6:193–206 Hellmann D, Becker G, Fingerhut C, Schmitter M, Rammelsberg P, Schindler HJ (2014) Methods of determining centric relation: a comparative study. J Craniomandib Function 6:193–206
17.
Zurück zum Zitat ISO 5725-1 2023. Accuracy (trueness and precision) of measurement methods and results. Part 1: General principles and definitions ISO 5725-1 2023. Accuracy (trueness and precision) of measurement methods and results. Part 1: General principles and definitions
19.
Zurück zum Zitat Hellmann D, Türp JC (2022) Interocclusal Registration in Splint Therapie. In: Schindler HJ, Türp JC (eds) Book title. Quintessence Publishing, Berlin Hellmann D, Türp JC (2022) Interocclusal Registration in Splint Therapie. In: Schindler HJ, Türp JC (eds) Book title. Quintessence Publishing, Berlin
20.
Zurück zum Zitat Reusch D, Landeweer GG, Feyen J (2015) Das Zentrikregistrat. Quintessenz 66:1–10 Reusch D, Landeweer GG, Feyen J (2015) Das Zentrikregistrat. Quintessenz 66:1–10
Metadaten
Titel
Comparison of the accuracy of different types of bite recordings - an in vitro study
verfasst von
Daniel Hellmann
Sarah Krumpa
Patrick Trautner
Hans J. Schindler
Marc Schmitter
Julian Boldt
Publikationsdatum
01.04.2024
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 4/2024
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-024-05637-y

Weitere Artikel der Ausgabe 4/2024

Clinical Oral Investigations 4/2024 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.