Skip to main content
Erschienen in: Clinical Oral Investigations 5/2024

Open Access 01.05.2024 | Research

Effect of material composition and thickness of orthodontic aligners on the transmission and distribution of forces: an in vitro study

verfasst von: Tarek M. Elshazly, Christoph Bourauel, Ahmed Ismail, Omar Ghoraba, Mostafa Aldesoki, Damiano Salvatori, Hanaa Elattar, Abdulaziz Alhotan, Yasmine Alkabani

Erschienen in: Clinical Oral Investigations | Ausgabe 5/2024

Abstract

Objectives

To investigate the effects of material type and thickness on force generation and distribution by aligners.

Materials and methods

Sixty aligners were divided into six groups (n = 10): one group with a thickness of 0.89 mm using Zendura Viva (Multi-layer), four groups with a thickness of 0.75 mm using Zendura FLX (Multi-layer), CA Pro (Multi-layer), Zendura (Single-layer), and Duran (Single-layer) sheets, and one group with a thickness of 0.50 mm using Duran sheets. Force measurements were conducted using Fuji® pressure-sensitive films.

Results

The lowest force values, both active and passive, were recorded for the multi-layered sheets: CA Pro (83.1 N, 50.5 N), Zendura FLX (88.9 N, 60.7 N), and Zendura Viva (92.5 N, 68.5 N). Conversely, the highest values were recorded for the single-layered sheets: Duran (131.9 N, 71.8 N) and Zendura (149.7 N, 89.8 N). The highest force was recorded at the middle third of the aligner, followed by the incisal third, and then the cervical third. The net force between the incisal and cervical thirds (FI-FC) showed insignificant difference across different materials. However, when comparing the incisal and middle thirds, the net force (FI-FM) was higher with single-layered materials. Both overall force and net force (FI-FM) were significantly higher with 0.75 mm compared to those with a thickness of 0.50 mm.

Conclusions

Multi-layered aligner materials exert lower forces compared to their single-layered counterparts. Additionally, increased thickness in aligners results in enhanced retention and greater force generation. For effective bodily tooth movement, thicker and single-layered rigid materials are preferred.

Clinical relevance

This research provides valuable insights into the biomechanics of orthodontic aligners, which could have significant clinical implications for orthodontists. Orthodontists might use this information to more effectively tailor aligner treatments, considering the specific tooth movement required for each individual patient. In light of these findings, an exchangeable protocol for aligner treatment is suggested, which however needs to be proven clinically. This protocol proposes alternating between multi-layered and single-layered materials within the same treatment phase. This strategy is suggested to optimize treatment outcomes, particularly when planning for a bodily tooth movement.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

In the era of digital and aesthetic dentistry, orthodontic aligners have increasingly become a preferred choice over traditional braces, thanks to their transparency and comfort [1]. Additionally, clear aligners are often the treatment of choice for adults who are more prone to periodontitis and gingivitis [2]. They are custom-made, removable splints, typically produced through the thermoforming process of plastic sheets. Each aligner in the treatment series is specifically designed to achieve a tooth’s translation of 0.2 mm or a rotation of about 2° over 1 to 2 weeks [35]. These sheets can be made of either conventional polymers [6, 7] or, more recently, smart polymers [8, 9].
The force system of aligners is complex, with multiple factors influencing the treatment outcomes [10]. The biomechanical behavior of aligners is determined by factors such as their material properties [11, 12], thickness [1315], adaptation to teeth [16], extension and trimming design [1721], and the amount of activation [15, 22]. Despite ongoing advancements in the field of aligners, discrepancies still exist between the planned virtual outcomes and the actual clinical results [3, 6]. The force system of aligners has been extensively studied using various methods, including numerical finite element method [15, 2325], together with experimental methods such as force sensors [26], pressure-sensitive films [18, 2729], and customized biomechanical systems [21, 3032].
Pressure-sensitive films, unlike standard sensors, have a reduced thickness, minimizing interference during testing with aligners and requiring less relief. This results in more user-friendly testing conditions. These films can directly measure the pressure between two surfaces, offering a rapid, straightforward, and dry measurement method [18]. Nevertheless, they are sensitive to technique and are significantly influenced by temperature, light, humidity, and load-rate [33]. They are available in two forms (mono-sheet and two-sheet), each is supplied with a range of sensitivity options. The two-sheet form comprises an A-transfer film and a C-developer film, with a combined thickness of about 100 μm. The A-film contains microcapsules that rupture under pressure, releasing chemicals that react with an active layer on the C-film. The resulting change in optical density, from pale pink to dark red, indicates the pressure intensity [34]. A specialized scanner can digitize these films, converting them into numerical and visual data [18].
Pressure-sensitive films were initially introduced in orthodontics to assess the occlusal changes after the end of treatment [3537], however, Barbagallo et al. [28] were among the first to employ these films for measuring the force exerted by orthodontic aligners. More recently, Cervinara et al. [27] employed them to analyze the force distribution applied by aligners to the upper central incisors. Elshazly et al. [18] investigated the impact of aligner trimming line design on force levels and distribution using the same technique. Additionally, Zamani et al. [29] measured forces generated by both passive and active aligners, especially with different types of attachments.
Despite the growing number of research on orthodontic aligners, the scientific literature on their biomechanical behavior still lacks comprehensive data. Many factors affect the resulting movement, including root shape and length and the point of contact between aligner and tooth. Pure translations are hardly achieved with clear aligners, because by their nature it is not possible to accurately predict the point of force application and control the root. Therefore, the aim of the current study is to shed light on how aligner material composition and thickness might affect the magnitude and distribution of forces on the facial surface of a maxillary central incisor when a facio-lingual bodily movement was planned. To this end, we have employed pressure-sensitive films, a methodology that, to our knowledge, has not been previously explored in this context.

Materials and methods

Pressure-sensitive films (Fuji® Prescale Film; Fuji Film, Tokyo, Japan) were used to measure the forces exerted by orthodontic aligners made of various materials. The optimal parameters applied in this study were based on a sensitivity analysis reported in a recent study [18]. A digital model of the upper dental arch, including all sixteen teeth (Digimation Corp., St Rose, Louisiana, USA) of a dentulous maxilla, was generated and imported as a stereolithography (STL) file into an advanced 3D image processing and editing software (3-matic 16.0; Materialise, Leuven, Belgium). This model was digitally redesigned using the software tools, resulting in three district models, each serving a different purpose in the current study.
The first model was tailored for the thermoforming process. It was designed as an aligned model with the teeth in their correct positions, free of malposition. The model height was measured 15 mm from the occlusal table to the model base. Additionally, a shallow depression was intentionally designed 2 mm away from the gingival margin of the teeth to ensure consistent and standardized aligner trimming (Fig. 1). The second model, also an aligned design, included a created 100 μm space around the four incisors and their corresponding gingival areas (housing space). This space was introduced to offset the inherent thickness of the pressure-sensitive films, which are 100 μm thick according to the data provided by the manufacturer (Fig. 1). The second model was used for passive force measurements, which indicate the aligner’s retention by measuring the force exerted between the aligned teeth and the aligner. In the third model, the right central incisor (Tooth 11) was bodily translated 0.2 mm facially, and the 100 μm housing space was also included. This model was designed for active force measurements, evaluating the force exerted between the malaligned tooth and the aligner. These models were printed with a resin (P pro resin; Straumann, Basel, Switzerland) using a digital light processing (DLP) 3D printer (P20+; Straumann, Basel, Switzerland), whose minimum accuracy is 34 μm.
Five thermoforming materials were used (as detailed in Table 1): Zendura FLX, Zendura Viva, CA Pro, Zendura, and Duran. All aligners were fabricated from sheets of the same 0.75 mm thickness (except Zendura Viva at 0.89 mm) and were trimmed to a straight 2 mm-extended trimming line design (n = 10) (Fig. 1). Additionally, to investigate the effects of aligner thickness, a further group (n = 10) of Duran sheets with a thickness of 0.50 mm was produced for comparison with the 0.75 mm thickness aligners made from the same material. In total, 60 aligners were fabricated (Fig. 2).
The thermoforming process was conducted according to the manufacturer’s specifications for each material and thickness (Table 1), using a thermoforming device (Biostar; Scheu-dental GmbH, Iserlohn, Germany). The 3D-printed model was consistently centered on the device platform for each fabrication to minimize inhomogeneity when deep drawing the sheets over the model. All aligners were produced by a single trained technician using the same 3D-printed models.
Table 1
Data on aligner sheets used in the current study (Manufacturers’ data)
Name
Manufacturer
Thickness/
Thermoforming Code
Thermoforming conditions
Material composition
Duran®
Scheu-Dental
(Iserlohn, Germany)
0.75 mm / Code (112)
Heating for 25 s at 220 °C, and pressure-forming at 4.8 bar, then cooling for 60 s
Single-layered sheet of Polyethylene terephthalate glycol-modified (PETG)
0.50 mm / Code (101)
Heating for 20 s at 220 °C, and pressure-forming at 4.8 bar, then cooling for 20 s
CA® Pro
Scheu-Dental
(Iserlohn, Germany)
0.75 mm /
Code (112)
Heating for 25 s at 220 °C, and pressure-forming at 4.8 bar, then cooling for 60 s
Three-layer sheet of a soft thermoplastic elastomeric layer between two hard layers of co-polyester
Zendura FLX™
Bay Materials
(Fremont, USA)
0.75 mm / Code (162)
Heating for 50 s at 220 °C, and pressure-forming at 5.8 bar, then cooling for 60 s
Three-layer sheet of a soft thermoplastic elastomeric layer between two hard layers of co-polyester
Zendura Viva™
Bay Materials
(Fremont, USA)
0.89 mm / Code (162)
Heating for 50 s at 220 °C, and pressure-forming at 5.8 bar, then cooling for 60 s
Three-layer sheet of a soft thermoplastic elastomeric layer between two hard layers of co-polyester
Zendura™
Bay Materials
(Fremont, USA)
0.75 mm / Code (162)
Heating for 50 s at 220 °C, and pressure-forming at 5.8 bar, then cooling for 60 s
Single-layered sheet of thermoplastic polyutherane (TPU).
In this study, the two-sheet type of pressure-sensitive film was utilized for force measurements. Each aligner was tested for both passive and active forces. To record active forces (between the malaligned third printed model and the adapted aligner), the low-pressure (LW) films with a measuring range of 2.5–10.0 MPa were used. For recording the passive forces (between the aligned second printed model and the adapted aligner), super-low-pressure (LLW) films, with a measuring range of 0.5–2.5 MPa were employed.
The films were precisely cut and seated with extreme caution to fit the designed housing space. Aligners were seated with extreme caution to prevent inadvertent pressure during the measurements. A single, well-trained operator conducted all the measurements. Room humidity and temperature were monitored using an indoor digital climate station (Technoline WS 9440 Indoor climate station; Technotrade GmbH, Wildau, Germany) during scanning. The recorded values for humidity and temperature (35 ± 4% and 25 ± 3 °C, respectively) were input into the scanning software to be factored into the measurement calculations.
Each pressurized film was scanned using a special scanner (EPSON perfection V300 series; SEIKO Epson CORPORATION, Japan) with a resolution of 0.125 (200 dpi), as recommended by the manufacturer 1. The force was digitalized and quantified using coupled software (FPD-8010E analysis system; Fuji® Film, Tokyo, Japan). This software enables the direct calculation of force values, which is determined by multiplying the average pressure (MPa) by the pressurized area (mm2), as per the software manual.
Force = Pressure × area
Force values (N) at the three thirds [Incisal (I), Middle (M), Cervical (C)] of the facial surface of (Tooth 11), as well as the overall force (N) over the facial surface of the tooth were recorded (Fig. 1). Additionally, for each aligner, the passive force was subtracted from the active force, and this resultant value (absolute force) was reported. The absolute force might reflect how the material responds to deformation.
Moreover, the distribution of forces (FC, FM, and FI) relative to the center of resistance (CR) is crucial in determining whether the orthodontic aligner treatment results in tipping or generates a couple of forces to promote bodily movement [6]. Therefore, the net force (FI-FC) between the active forces at the incisal third (I) and cervical third (C), as well as the net force (FI-FM) between the active forces at the incisal third (I) and the middle third (M) were calculated for each group. This was done to investigate the effect of the material and thickness on the moment of force, and consequently, on the type of tooth movement (Fig. 3).

Statistical analysis

Numerical force values were presented as mean ± standard deviation. Normality was assessed by examining data distribution and applying the Shapiro-Wilk test. As the data showed a parametric distribution, they were analyzed using one-way ANOVA followed by a post-hoc Tukey HSD Test. The significance level (α) was set at p ≤ 0.05. Statistical analysis was performed using IBM SPSS Statistics version 25 for Windows (IBM, Endicott, NY, USA).

Results

The active force values generated across the entire facial surface of tooth 11 ranged from 83.1 to 149.7 N. Passive force values varied from 50.5 to 89.8 N, while the absolute force values spanned from 24.0 to 60.1 N. The highest force values were observed in the single-layered materials (Duran and Zendura), with no significant differences between them. Conversely, the lowest force values were noted in the multi-layered materials (CA Pro, Zendura FLX, and Zendura Viva), with no significant differences among them in terms of active and absolute forces (Fig. 4).
The distribution of forces across the facial surface of Tooth 11 was uneven, with concentrations of force at specific positions (Figs. 1, 4 and 5). The force varied significantly at different positions on the tooth, with some areas experiencing substantially higher forces than others. Dividing the tooth surface into three equal thirds revealed that the active force at the middle third (FM) was significantly higher than that at the incisal (FI) and cervical thirds (FC). Statistical analysis showed no significant difference in the net active force (FI-FC) among different materials. However, when comparing the net active force (FI-FM), single-layered materials exhibited higher net forces than multi-layered materials (Table 2).
Furthermore, aligners made from Duran material with a thickness of 0.75 mm displayed higher forces than those with a thickness of 0.5 mm. There was no significant difference in the net active force (FI-FC) between the two thicknesses. However, the net active force (FI-FM) was higher in the thicker aligners (Table 3).
Table 2
Active forces (in N) exerted on the facial surface of a maxillary central incisor by aligners made of different thermoformed materials. Forces were recorded at the three thirds of the facial surface: namely Cervical (C), Middle (M), Incisal (I), as well as the net active forces (FI-FC) between the incisal (I) and the cervical thirds (C) and the net active forces (FI-FM) between the incisal (I) and the middle thirds (M)
Tooth third
Active Force (N) (Mean ± SD)
p-value
Zendura-FLX
Zendura-Viva
CA Pro
Zendura
Duran
C
16.0 ± 11.4ABb
12.7 ± 4.9Bc
10.1 ± 5.1Bc
24.4 ± 7.1Ac
19.0 ± 5.7ABc
0.008*
M
45.4 ± 13.3Ba
50.0 ± 11.0Ba
44.4 ± 8.0Ba
85.9 ± 12.1Aa
75.7 ± 13.1Aa
< 0.01*
I
27.5 ± 6.3Bb
29.8 ± 9.8ABb
28.6 ± 9.7ABb
39.4 ± 6.6Ab
37.2 ± 11.5ABb
< 0.01*
p-value
< 0.01*
< 0.01*
< 0.01*
< 0.01*
< 0.01*
 
FI-FC
11.5A
17.1A
18.5A
15.0A
18.2A
0.899
FI-FM
-17.9B
-20.2B
-15.8B
-46.5A
-38.5A
< 0.01*
Different uppercase lowercase superscript letters indicate a statistically significant difference within the same horizontal row and vertical column respectively, *significant (p < 0.05)
Table 3
Active, passive, and absolute forces (in N) exerted on the facial surface of a maxillary central incisor by two different thicknesses of aligners made of Duran sheets. Forces were recorded at the three thirds of the facial surface: namely Cervical (C), Middle (M), Incisal (I), as well as the net active forces (FI-FC) between the incisal (I) and the cervical thirds (C) and the net active forces (FI-FM) between the incisal (I) and the middle thirds (M)
 
Force in N (Mean ± SD)
p-value
0.5
0.75
Active
86.6 ± 16.2B
131.9 ± 22.8A
p < 0.01*
Passive
57.0 ± 7.9B
71.8 ± 8.9A
p < 0.01*
Absolute
29.6 ± 14.9B
60.1 ± 23.7A
p < 0.01*
Tooth third
Active Force in N (Mean ± SD)
p-value
0.5
0.75
C
9.4 ± 4.2Bc
19.0 ± 5.7Ac
p < 0.01*
M
45.5 ± 10.0Ba
75.7 ± 13.1Aa
p < 0.01*
I
31.7 ± 8.3Ab
37.2 ± 11.5Ab
p < 0.01*
p-value
p < 0.01*
p < 0.01*
 
FI-FC
22.3A
18.2A
0.308
FI-FM
-13.8B
-38.5A
 
Different uppercase lowercase superscript letters indicate a statistically significant difference within the same horizontal row and vertical column respectively, *significant (p < 0.05)

Discussion

Understanding the biomechanical system of orthodontic aligners is crucial for achieving efficient and successful treatment outcomes. Investigating the material properties of clear aligners provides clinicians with insights into their limitations [38]. The incorporation of innovative materials with enhanced properties has the potential to significantly improve the efficacy of orthodontic aligner treatments [8, 9]. However, most aligner suppliers still rely on conventional thermoforming techniques. This method can introduce variations in material properties [7] and lead to geometric inaccuracies [18], affecting both the fit of the aligner and the forces transmitted to the teeth. Thus, a comprehensive study is needed to understand how the type and thickness of thermoplastic materials influence the biomechanics of aligners. Such investigations are crucial for controlling the forces exerted and achieving more predictable outcomes in tooth movement. To our knowledge, the influence of these factors has yet to be thoroughly explored, particularly using the pressure-sensitive films.
The absence of periodontal ligament (PDL) representation in orthodontic experimental studies often results in higher forces than the physiological orthodontic limit (0.1–1.2 N) [11]. The force values obtained in this study (83.1–149.7 N) are significantly higher than those reported in the literature. This disparity may be attributed to the innovative methodology employed, which includes the use of pressure-sensitive films and a specialized scanner equipped with software capable of directly quantifying force values. However, these pressure-sensitive films have limitations, as they provide localized one-dimensional force measurements on a single tooth surface. In contrast, clear aligners exert three-dimensional forces simultaneously across multiple tooth positions and directional axes, resulting in a lower overall resultant force. This discrepancy represents a limitation of the current research approach. In addition, the geometrical deviations in the manufacturing process of the model (3D Printing), the aligner (thermoforming), and the pressure film itself may play a significant role in the determination of the forces. While the offset of 100 μm was designed to compensate for the film thickness, these variations may add up and affect the actual contact between the aligner and the teeth, resulting in a shift toward higher forces. Another factor is that the dry conditions and room temperature reduce the stiffness of the aligner material compared to the intraoral conditions.
Utilizing pressure-sensitive films, Barbagallo et al. [28] reported force values of approximately 28.0 N in an in vivo study. Similarly, Cervinara et al. [27] reported values in pressure units (around 3.3 MPa), not in forces units. Although measured in different units, our force values are comparable to Cervinara’s findings, considering the average measured pressurized surface area in our experiment was about 40 mm2, and the force (N) is calculated as the product of pressure (MPa) and area (mm2).
Thermoplastic materials used in aligners exhibit viscoelastic behavior, meaning they inherently possess elastic and plastic characteristics. Consequently, when an aligner splint is deformed over the targeted tooth, these materials tend to partially return to their original shape. This inherent property is the fundamental basis for the generation of forces by orthodontic aligners employed for tooth movement [6]. The effectiveness of tooth movement with orthodontic aligners is determined by the force systems they generate, including both forces and moments. The ratio of moments to forces acting on the tooth can vary significantly and influence the type of tooth movement [39]. In removable orthodontic appliances, forces are typically applied to the crown of the tooth, away from the center of resistance (CR) in the root, creating a moment leading to tooth tipping. The magnitude of this moment is directly proportional to the applied force and the distance between the force application point and the CR. Consequently, altering the location of force application impacts the type of moment generated and, hence, the type of tooth movement. Specifically, as the applied force moves closer to the CR, the resulting tipping motion diminishes while the tendency for bodily translation of the tooth increases [6, 40]. Thus, the distribution and application point of the force on the tooth surface significantly affect the type of tooth movement, determining whether it is bodily or tipping. A bodily movement requires the application of a higher force at the cervical region than the incisal [21].
Consistent with previous studies [18, 27], the thermoformed orthodontic aligners in the current study exhibited close and intimate contact with the teeth, leading to the generation of passive forces. The higher levels of passive forces observed with the Zendura single-layered sheets suggest superior initial retention compared to some multi-layered sheets, like CA Pro and Zendura Viva. Similarly, the higher passive force generated with thicker Duran aligners indicates greater retention. A previous review by Upadhyay and Arqub [6] highlighted that intimate contact between aligners and teeth should facilitate a more uniform distribution of stress across the tooth’s surface. However, the tooth’s surface contour also plays a key role in determining how forces are distributed [15]. Consequently, uneven contact between the aligner and tooth surface was observed, resulting in areas of relief and others of close contact.
In line with the research by Lombardo et al. [41], our study found that the single-layered sheets (Zendura and Duran) showed higher absolute forces, indicating higher rigidity, while the multi-layered sheets (Zendura Viva, Zendura FLX, and CA Pro) exhibited lower absolute forces, indicating higher flexibility. Additionally, the active forces exerted by single-layered materials were higher than those generated by the multi-layered materials.
Moreover, the strength of forces varied across different positions of tooth surface, with the middle third consistently exhibiting the highest force intensity, followed by the incisal and then the cervical third, in agreement with prior studies [14, 17, 20]. This force distribution pattern makes achieving bodily tooth movement challenging and endorses more crown tipping. Rossini et al. [42] concluded similar findings in a systematic review. The net forces between the incisal and cervical thirds exhibited comparable values among different materials. However, the net forces between the incisal and middle thirds were higher with single-layered materials. This observation suggests an advantage in using rigid single-layered material for planning bodily tooth movement. It suggests an interchangeable protocol for aligner treatment, to be validated clinically, involving the use of flexible multi-layered material followed by rigid single-layered material within each treatment step. It should be noted that the results reflect the clinical situation at the beginning of the treatment step. In a clinical setting, the tooth is free to move in the palatal direction within the limits of the periodontal ligament. Thus, a new contact between aligner and tooth in the palatal surface will be established that will affect the total force system. Nevertheless, the results suggest that more rigid aligners tend to maintain a more uniform contact along the tooth length, thus are less prone to cause tipping movements when a bodily movement is planned.
The thickness of the aligner plays a crucial biomechanical role [20]. Variations in material thickness lead to changes in force-deformation characteristics, aligner stiffness, and the forces transmitted [14, 20]. Additionally, increased thickness results in greater local and overall deformations of the aligner, reducing tooth-to-aligner contact areas and, consequently, aligner retention [16]. This is consistent with the findings of the current study. The cervical region of a thermoformed aligner is particularly important as it experiences the most significant thinning during thermoforming [18]. As a result, it is more prone to deformation and irregular forces generation [17, 18]. The present study found that thicker aligners generated significantly higher active and passive forces compared to thinner ones, aligning with previous research [13, 22]. Moreover, the net active force (FI-FM) was higher with thicker aligner, promoting bodily tooth movement.
Several limitations of this in vitro study should be acknowledged:
1.
The technique-sensitivity of pressure films might lead to a wide variability in the measured force.
 
2.
Extra forces were unavoidably transmitted during the insertion and removal of the aligner, particularly in the presence of undercuts, existing by default in both passive and active aligners.
 
3.
The scanning analysis produced a two-dimensional image of a three-dimensional surface.
 
4.
The effect of the PDL and bone, which significantly contribute to the stress distribution in the orthodontic appliances, was not included.
 
5.
The precision of the aligners was affected by inherent variability introduced during the thermoforming and trimming. To minimize this variability, aligner fabrication via thermoforming strictly followed the manufacturer’s guidelines, using the same printed model for consistency. Additionally, a standardized guided straight trimming line design, consistently positioned 2 mm apical to the gingival line, was uniformly implemented for all aligners. This approach aimed to prevent additional finishing and polishing steps, which could negatively impact the mechanical properties of the aligner at the gingival region [17, 18]. Furthermore, the sample size was increased to ten aligners per group (n = 10) to enhance the statistical robustness of the study and account for residual variability.
 
Future research could apply the same methodology can be applied to explore various types of tooth movements. The suggested protocol alternating softer and more rigid aligners during each treatment step should be proven clinically. Additionally, there is potential to investigate the influence of attachments, including their shapes and positions, on force distribution and tooth movement dynamics. Moreover, integrating of 3D printing technology into aligner manufacturing is a promising path for investigation. This technology offers enhanced control over aligner design and thickness. Hence, this method could also facilitate an in-depth examination of the advantages of 3D-printed aligners compared to traditional thermoformed aligners.

Conclusion

Within the limitation of the current in vitro study the following observations can be drawn:
1.
When orthodontic aligners are used, the forces are not uniformly distributed across the tooth surface. Instead, they concentrate on specific repeatable areas, which can be identified as force application areas.
 
2.
The force distribution pattern on the tooth surface induced by aligners tends to favor tipping movements.
 
3.
The aligner material type notably influences the force generation when aligner splint deformation occurs over a malaligned tooth. Compared to the single-layered sheets of Zendura and Duran, the three-layer sheets of Zendura Viva, Zendura FLX sheets and CA-Pro can generate lower initial forces to the teeth.
 
4.
The rigid single-layered aligner materials may promote bodily tooth movement, more than the flexible multi-layered aligner materials.
 
5.
An exchangeable protocol for aligner treatment is suggested, which however needs to be proven clinically. This protocol involves using the flexible multi-layered material followed by the rigid single-layered material within each treatment step. This approach may optimize the aligner treatment outcomes, especially when a bodily movement of teeth is planned.
 

Acknowledgements

The authors thank the Researchers Supporting Project Number (RSPD2024R790), King Saud University, Riyadh, Saudi Arabia.

Declarations

Ethical approval

Not applicable.
Not applicable.

Research highlights

•Force distribution transferred to the tooth by aligners achieves a tipping motion.
•Single-layered aligner materials promote bodily tooth movement.
•Multi-layered aligner materials are more flexible and apply less force.
•A thicker aligner is more retentive and exerts more force to support bodily movement.
•An interchangeable protocol (Flexible/Rigid materials per each step) is advisable.

Compliance with ethics requirements

This article does not contain any studies with human or animal subjects.

Competing interests

The authors declare no competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Jetzt e.Med zum Sonderpreis bestellen!

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt bestellen und 100 € sparen!

e.Dent – Das Online-Abo der Zahnmedizin

Online-Abonnement

Mit e.Dent erhalten Sie Zugang zu allen zahnmedizinischen Fortbildungen und unseren zahnmedizinischen und ausgesuchten medizinischen Zeitschriften.

Literatur
1.
Zurück zum Zitat Ashari A, Mohamed AM (2016) Relationship of the Dental Aesthetic Index to the oral health-related quality of life. Angle Orthod 86(2):337–342CrossRefPubMed Ashari A, Mohamed AM (2016) Relationship of the Dental Aesthetic Index to the oral health-related quality of life. Angle Orthod 86(2):337–342CrossRefPubMed
2.
Zurück zum Zitat Jiang Q, Li J, Mei L et al (2018) Periodontal health during orthodontic treatment with clear aligners and fixed appliances: a meta-analysis. J Am Dent Assoc 149(8):712–720CrossRefPubMed Jiang Q, Li J, Mei L et al (2018) Periodontal health during orthodontic treatment with clear aligners and fixed appliances: a meta-analysis. J Am Dent Assoc 149(8):712–720CrossRefPubMed
3.
Zurück zum Zitat Tamer I, Öztas E, Marsan G (2019) Orthodontic treatment with clear aligners and the scientific reality behind their marketing: a literature review. Turkish J Orthod 32(4):241–246CrossRef Tamer I, Öztas E, Marsan G (2019) Orthodontic treatment with clear aligners and the scientific reality behind their marketing: a literature review. Turkish J Orthod 32(4):241–246CrossRef
5.
Zurück zum Zitat Mehta F, Mehta S (2014) Aligners: the rapidly growing trend in orthodontics around the world. Indian J Basic Appl Med Res 3:402–409 Mehta F, Mehta S (2014) Aligners: the rapidly growing trend in orthodontics around the world. Indian J Basic Appl Med Res 3:402–409
6.
Zurück zum Zitat Upadhyay M, Arqub SA (2021) Biomechanics of clear aligners: hidden truths & first principles. J World Fed Orthod 11(1):12–21CrossRefPubMed Upadhyay M, Arqub SA (2021) Biomechanics of clear aligners: hidden truths & first principles. J World Fed Orthod 11(1):12–21CrossRefPubMed
7.
Zurück zum Zitat Golkhani B, Weber A, Keilig L, Reimann S, Bourauel C (2022) Variation of the modulus of elasticity of aligner foil sheet materials due to thermoforming. J Orofac Orthop Der Kieferorthopädie 83(4):233–243CrossRef Golkhani B, Weber A, Keilig L, Reimann S, Bourauel C (2022) Variation of the modulus of elasticity of aligner foil sheet materials due to thermoforming. J Orofac Orthop Der Kieferorthopädie 83(4):233–243CrossRef
8.
Zurück zum Zitat Elshazly TM, Keilig L, Alkabani Y et al (2021) Primary evaluation of Shape Recovery of Orthodontic Aligners Fabricated from shape memory polymer (a Typodont Study). Dent J 9(3):31CrossRef Elshazly TM, Keilig L, Alkabani Y et al (2021) Primary evaluation of Shape Recovery of Orthodontic Aligners Fabricated from shape memory polymer (a Typodont Study). Dent J 9(3):31CrossRef
10.
Zurück zum Zitat Barone S, Paoli A, Razionale AV, Savignano R (2016) Design of Customised Orthodontic devices by Digital Imaging and CAD/FEM Modelling. Bioimaging 44–52 Barone S, Paoli A, Razionale AV, Savignano R (2016) Design of Customised Orthodontic devices by Digital Imaging and CAD/FEM Modelling. Bioimaging 44–52
11.
Zurück zum Zitat Elkholy F, Schmidt F, Jäger R, Lapatki BG (2016) Forces and moments delivered by novel, thinner PET-G aligners during labiopalatal bodily movement of a maxillary central incisor: an in vitro study. Angle Orthod 86(6):883–890CrossRefPubMedPubMedCentral Elkholy F, Schmidt F, Jäger R, Lapatki BG (2016) Forces and moments delivered by novel, thinner PET-G aligners during labiopalatal bodily movement of a maxillary central incisor: an in vitro study. Angle Orthod 86(6):883–890CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Ho CT, Huang YT, Chao CW, Huang TH, Kao CT (2021) Effects of different aligner materials and attachments on orthodontic behavior. J Dent Sci 16(3):1001–1009CrossRefPubMedPubMedCentral Ho CT, Huang YT, Chao CW, Huang TH, Kao CT (2021) Effects of different aligner materials and attachments on orthodontic behavior. J Dent Sci 16(3):1001–1009CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Liu DS, Chen YT (2015) Effect of thermoplastic appliance thickness on initial stress distribution in periodontal ligament. Adv Mech Eng 7(4):1687814015578362CrossRef Liu DS, Chen YT (2015) Effect of thermoplastic appliance thickness on initial stress distribution in periodontal ligament. Adv Mech Eng 7(4):1687814015578362CrossRef
14.
Zurück zum Zitat Hahn W, Dathe H, Fialka-Fricke J et al (2009) Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping. Am J Orthod Dentofac Orthop 136(1):12e1–12e7CrossRef Hahn W, Dathe H, Fialka-Fricke J et al (2009) Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping. Am J Orthod Dentofac Orthop 136(1):12e1–12e7CrossRef
15.
Zurück zum Zitat Elshazly TM, Bourauel C, Aldesoki M et al (2022) Computer-aided finite element model for biomechanical analysis of orthodontic aligners. Clin Oral Investig 27(1):115–124CrossRefPubMed Elshazly TM, Bourauel C, Aldesoki M et al (2022) Computer-aided finite element model for biomechanical analysis of orthodontic aligners. Clin Oral Investig 27(1):115–124CrossRefPubMed
17.
Zurück zum Zitat Cowley DP, Mah J, O’Toole B (2012) The effect of gingival-margin design on the retention of thermoformed aligners. J Clin Orthod JCO 46(11):697PubMed Cowley DP, Mah J, O’Toole B (2012) The effect of gingival-margin design on the retention of thermoformed aligners. J Clin Orthod JCO 46(11):697PubMed
19.
Zurück zum Zitat Brown BE (2021) Effect of Gingival Margin Design on Clear Aligner Material strain and force delivery. University of Minnesota Brown BE (2021) Effect of Gingival Margin Design on Clear Aligner Material strain and force delivery. University of Minnesota
20.
Zurück zum Zitat Gao L, Wichelhaus A (2017) Forces and moments delivered by the PET-G aligner to a maxillary central incisor for palatal tipping and intrusion. Angle Orthod 87(4):534–541CrossRefPubMedPubMedCentral Gao L, Wichelhaus A (2017) Forces and moments delivered by the PET-G aligner to a maxillary central incisor for palatal tipping and intrusion. Angle Orthod 87(4):534–541CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Min S, Hwang CJ, Yu HS, Lee SB, Cha JY (2010) The effect of thickness and deflection of orthodontic thermoplastic materials on its mechanical properties. Korean J Orthod 40(1):16–26CrossRef Min S, Hwang CJ, Yu HS, Lee SB, Cha JY (2010) The effect of thickness and deflection of orthodontic thermoplastic materials on its mechanical properties. Korean J Orthod 40(1):16–26CrossRef
23.
Zurück zum Zitat Barone S, Paoli A, Razionale AV, Savignano R (2016) Computer aided modelling to simulate the biomechanical behaviour of customised orthodontic removable appliances. Int J Interact Des Manuf 10(4):387–400CrossRef Barone S, Paoli A, Razionale AV, Savignano R (2016) Computer aided modelling to simulate the biomechanical behaviour of customised orthodontic removable appliances. Int J Interact Des Manuf 10(4):387–400CrossRef
24.
Zurück zum Zitat Cai Y, Yang X, He B, Yao J (2015) Finite element method analysis of the periodontal ligament in mandibular canine movement with transparent tooth correction treatment. BMC Oral Health 15(1):1–11CrossRef Cai Y, Yang X, He B, Yao J (2015) Finite element method analysis of the periodontal ligament in mandibular canine movement with transparent tooth correction treatment. BMC Oral Health 15(1):1–11CrossRef
25.
Zurück zum Zitat Gomez JP, Peña FM, Martinez V, Giraldo DC, Cardona CI (2015) Initial force systems during bodily tooth movement with plastic aligners and composite attachments: a three-dimensional finite element analysis. Angle Orthod 85(3):454–460CrossRefPubMed Gomez JP, Peña FM, Martinez V, Giraldo DC, Cardona CI (2015) Initial force systems during bodily tooth movement with plastic aligners and composite attachments: a three-dimensional finite element analysis. Angle Orthod 85(3):454–460CrossRefPubMed
26.
Zurück zum Zitat Xiang B, Wang X, Wu G et al (2021) The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva. Sci Rep 11(1):1–10CrossRef Xiang B, Wang X, Wu G et al (2021) The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva. Sci Rep 11(1):1–10CrossRef
27.
Zurück zum Zitat Cervinara F, Cianci C, De Cillis F et al (2019) Experimental study of the pressures and points of application of the forces exerted between aligner and tooth. Nanomaterials 9(7):1010CrossRefPubMedPubMedCentral Cervinara F, Cianci C, De Cillis F et al (2019) Experimental study of the pressures and points of application of the forces exerted between aligner and tooth. Nanomaterials 9(7):1010CrossRefPubMedPubMedCentral
28.
Zurück zum Zitat Barbagallo LJ, Shen G, Jones AS, Swain MV, Petocz P, Darendeliler MA (2008) A novel pressure film approach for determining the force imparted by clear removable thermoplastic appliances. Ann Biomed Eng 36(2):335–341CrossRefPubMed Barbagallo LJ, Shen G, Jones AS, Swain MV, Petocz P, Darendeliler MA (2008) A novel pressure film approach for determining the force imparted by clear removable thermoplastic appliances. Ann Biomed Eng 36(2):335–341CrossRefPubMed
30.
Zurück zum Zitat Simon M, Keilig L, Schwarze J, Jung BA, Bourauel C (2014) Forces and moments generated by removable thermoplastic aligners: incisor torque, premolar derotation, and molar distalization. Am J Orthod Dentofac Orthop 145(6):728–736CrossRef Simon M, Keilig L, Schwarze J, Jung BA, Bourauel C (2014) Forces and moments generated by removable thermoplastic aligners: incisor torque, premolar derotation, and molar distalization. Am J Orthod Dentofac Orthop 145(6):728–736CrossRef
31.
Zurück zum Zitat Elkholy F, Schmidt F, Jäger R, Lapatki BG (2017) Forces and moments applied during derotation of a maxillary central incisor with thinner aligners: an in-vitro study. Am J Orthod Dentofac Orthop 151(2):407–415CrossRef Elkholy F, Schmidt F, Jäger R, Lapatki BG (2017) Forces and moments applied during derotation of a maxillary central incisor with thinner aligners: an in-vitro study. Am J Orthod Dentofac Orthop 151(2):407–415CrossRef
32.
Zurück zum Zitat Hahn W, Engelke B, Jung K et al (2010) Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor. Angle Orthod 80(2):239–246CrossRefPubMedPubMedCentral Hahn W, Engelke B, Jung K et al (2010) Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor. Angle Orthod 80(2):239–246CrossRefPubMedPubMedCentral
33.
Zurück zum Zitat Liggins AB (1997) Finlay JB. Image-averaging in the analysis of data from pressure-sensitive film. Exp Tech 21(3):19–22CrossRef Liggins AB (1997) Finlay JB. Image-averaging in the analysis of data from pressure-sensitive film. Exp Tech 21(3):19–22CrossRef
35.
Zurück zum Zitat Sultana MH, Yamada K, Hanada K (2002) Changes in occlusal force and occlusal contact area after active orthodontic treatment: a pilot study using pressure-sensitive sheets. J Oral Rehabil 29(5):484–491CrossRefPubMed Sultana MH, Yamada K, Hanada K (2002) Changes in occlusal force and occlusal contact area after active orthodontic treatment: a pilot study using pressure-sensitive sheets. J Oral Rehabil 29(5):484–491CrossRefPubMed
36.
Zurück zum Zitat Choi YJ, Chung CJ, Kim KH (2010) Changes in occlusal force and occlusal contact area after orthodontic treatment. Korean J Orthod 40(3):176–183CrossRef Choi YJ, Chung CJ, Kim KH (2010) Changes in occlusal force and occlusal contact area after orthodontic treatment. Korean J Orthod 40(3):176–183CrossRef
37.
Zurück zum Zitat Yoon W, Hwang S, Chung C, Kim KH (2017) Changes in occlusal function after extraction of premolars: 2-year follow-up. Angle Orthod 87(5):703–708CrossRefPubMedPubMedCentral Yoon W, Hwang S, Chung C, Kim KH (2017) Changes in occlusal function after extraction of premolars: 2-year follow-up. Angle Orthod 87(5):703–708CrossRefPubMedPubMedCentral
38.
Zurück zum Zitat Yassir YA, Nabbat SA, McIntyre GT, Bearn DR (2022) Clinical effectiveness of clear aligner treatment compared to fixed appliance treatment: an overview of systematic reviews. Clin Oral Investig 26(3):1–18CrossRef Yassir YA, Nabbat SA, McIntyre GT, Bearn DR (2022) Clinical effectiveness of clear aligner treatment compared to fixed appliance treatment: an overview of systematic reviews. Clin Oral Investig 26(3):1–18CrossRef
39.
Zurück zum Zitat Upadhyay M, Nanda R (2014) Biomechanics in orthodontics. Esthet Biomech Orthod 152(1):74–89 Upadhyay M, Nanda R (2014) Biomechanics in orthodontics. Esthet Biomech Orthod 152(1):74–89
40.
Zurück zum Zitat Ashraf K, Kulshrestha R, Tandom R, Kaur H, Mathur P (2018) Biomechanics in orthodontics-a review (part 1). Indian J Orthod Dentofac Res 4:114–124 Ashraf K, Kulshrestha R, Tandom R, Kaur H, Mathur P (2018) Biomechanics in orthodontics-a review (part 1). Indian J Orthod Dentofac Res 4:114–124
41.
Zurück zum Zitat Lombardo L, Martines E, Mazzanti V, Arreghini A, Mollica F, Siciliani G (2016) Stress relaxation properties of four orthodontic aligner materials: a 24-hour in vitro study. Angle Orthod 87(1):11–18CrossRefPubMedPubMedCentral Lombardo L, Martines E, Mazzanti V, Arreghini A, Mollica F, Siciliani G (2016) Stress relaxation properties of four orthodontic aligner materials: a 24-hour in vitro study. Angle Orthod 87(1):11–18CrossRefPubMedPubMedCentral
42.
Zurück zum Zitat Rossini G, Parrini S, Castroflorio T, Deregibus A, Debernardi CL (2015) Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review. Angle Orthod 85(5):881–889CrossRefPubMed Rossini G, Parrini S, Castroflorio T, Deregibus A, Debernardi CL (2015) Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review. Angle Orthod 85(5):881–889CrossRefPubMed
Metadaten
Titel
Effect of material composition and thickness of orthodontic aligners on the transmission and distribution of forces: an in vitro study
verfasst von
Tarek M. Elshazly
Christoph Bourauel
Ahmed Ismail
Omar Ghoraba
Mostafa Aldesoki
Damiano Salvatori
Hanaa Elattar
Abdulaziz Alhotan
Yasmine Alkabani
Publikationsdatum
01.05.2024
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 5/2024
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-024-05662-x

Weitere Artikel der Ausgabe 5/2024

Clinical Oral Investigations 5/2024 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.